Shaking table tests and theoretical analysis were conducted to study the dynamic performance of cable net facade with consideration of glass panels under earthquake. Firstly,the dynamic response of cable net faade u...Shaking table tests and theoretical analysis were conducted to study the dynamic performance of cable net facade with consideration of glass panels under earthquake. Firstly,the dynamic response of cable net faade under earthquake was investigated with shaking table test. Then the working mechanism of glass panels in coordination with cable net was proposed. Accordingly,a numerical simulation model of glass panel's working in coordination with cable net was built for the dynamic analysis.And then the seismic response was analyzed with this model theoretically. The study indicates that the seismic response of the cable net with glass panels on most occasions is mainly decided by the symmetric modes,and the first vibration mode is dominant. The damping of cable net facade is mainly decided by glass panels. And it is very good for cable net faade to restrain its dynamic response under earthquake.展开更多
3 GPP LTE has approved uplink intra-cell power control and defined overload indicator (OI) for uplink inter-cell power contrQ1 to mitigate the inter-cell interference (ICI), respectively. In this pa- per, we propo...3 GPP LTE has approved uplink intra-cell power control and defined overload indicator (OI) for uplink inter-cell power contrQ1 to mitigate the inter-cell interference (ICI), respectively. In this pa- per, we propose a hierarchical power control ( HPC ) scheme where intra-eell and inter-cell power controls interact with each other. The inter-cell power control eommand is generated by radio re- source management (RRM) entity according to the ICI-load model together with the current ICI and served load information. This ICI-load model is proposed as a guideline for coordination among cells to enable the system to approach its system specific interference over thermal noise (IoT) work area. Simulation results show that for HPC scheme, the system' s IoT is well controlled to fit its pre-de- fined work area and the power efficiency is improved significantly. Our proposed scheme is also ro- bust to different settings of its inter-cell power control period.展开更多
基金Sponsored by National "Eleventh Five-Year" Technological Supporting Plan (Grant No.2006BAJ02A05)National Natural Science Foundation of China(Grant No.50908044)+1 种基金China Postdoctoral Foundation (Grant No.20070420164)Shenzhen Technical Foundation (Grant No.20080624_1554)
文摘Shaking table tests and theoretical analysis were conducted to study the dynamic performance of cable net facade with consideration of glass panels under earthquake. Firstly,the dynamic response of cable net faade under earthquake was investigated with shaking table test. Then the working mechanism of glass panels in coordination with cable net was proposed. Accordingly,a numerical simulation model of glass panel's working in coordination with cable net was built for the dynamic analysis.And then the seismic response was analyzed with this model theoretically. The study indicates that the seismic response of the cable net with glass panels on most occasions is mainly decided by the symmetric modes,and the first vibration mode is dominant. The damping of cable net facade is mainly decided by glass panels. And it is very good for cable net faade to restrain its dynamic response under earthquake.
基金Supported by the National High Technology Research and Development Programme of China(No.2009AA011501)International S&T Cooperation Program of Shanghai Municipality(No.09530702500&10220712100)Major Project of Shanghai Municipality(No.09511501100)
文摘3 GPP LTE has approved uplink intra-cell power control and defined overload indicator (OI) for uplink inter-cell power contrQ1 to mitigate the inter-cell interference (ICI), respectively. In this pa- per, we propose a hierarchical power control ( HPC ) scheme where intra-eell and inter-cell power controls interact with each other. The inter-cell power control eommand is generated by radio re- source management (RRM) entity according to the ICI-load model together with the current ICI and served load information. This ICI-load model is proposed as a guideline for coordination among cells to enable the system to approach its system specific interference over thermal noise (IoT) work area. Simulation results show that for HPC scheme, the system' s IoT is well controlled to fit its pre-de- fined work area and the power efficiency is improved significantly. Our proposed scheme is also ro- bust to different settings of its inter-cell power control period.