The Jiangmen Underground Neutrino Observatory(JUNO)is a large liquid scintillator detector designed to explore many topics in fundamental physics.In this study,the potential of searching for proton decay in the p→νK...The Jiangmen Underground Neutrino Observatory(JUNO)is a large liquid scintillator detector designed to explore many topics in fundamental physics.In this study,the potential of searching for proton decay in the p→νK^(+)mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification.Moreover,the excellent energy resolution of JUNO permits suppression of the sizable background caused by other delayed signals.Based on these advantages,the detection efficiency for the proton decay via p→νK^(+)is 36.9%±4.9%with a background level of 0.2±0.05(syst)±0.2(stat)events after 10 years of data collection.The estimated sensitivity based on 200 kton-years of exposure is 9.6×1033 years,which is competitive with the current best limits on the proton lifetime in this channel and complements the use of different detection technologies.展开更多
To improve the understanding of the transport mechanism in shale gas reservoirs and build a theoretical basic for further researches on productivity evaluation and efficient exploitation, various gas transport mechani...To improve the understanding of the transport mechanism in shale gas reservoirs and build a theoretical basic for further researches on productivity evaluation and efficient exploitation, various gas transport mechanisms within a shale gas reservoir exploited by a horizontal well were thoroughly investigated, which took diffusion, adsorption/desorption and Darcy flow into account. The characteristics of diffusion in nano-scale pores in matrix and desorption on the matrix surface were both considered in the improved differential equations for seepage flow. By integrating the Langmuir isotherm desorption items into the new total dimensionless compression coefficient in matrix, the transport function and seepage flow could be formalized, simplified and consistent with the conventional form of diffusion equation. Furthermore, by utilizing the Laplace change and Sethfest inversion changes, the calculated results were obtained and further discussions indicated that transfer mechanisms were influenced by diffusion, adsorption/desorption. The research shows that when the matrix permeability is closed to magnitude of 10^-9D, the matrix flow only occurs near the surfacial matrix; as to the actual production, the central matrix blocks are barely involved in the production; the closer to the surface of matrix, the lower the pressure is and the more obvious the diffusion effect is; the behavior of adsorption/desorption can increase the matrix flow rate significantly and slow down the pressure of horizontal well obviously.展开更多
BACKGROUND Mechanical ventilation can lead to the severe impairment of the metabolic pathway of alveolar surfactants,inactivating alveolar surfactants and significantly reducing lung-chest compliance.The cardiopulmona...BACKGROUND Mechanical ventilation can lead to the severe impairment of the metabolic pathway of alveolar surfactants,inactivating alveolar surfactants and significantly reducing lung-chest compliance.The cardiopulmonary function of elderly patients usually reduced to a certain extent,and there are lung complications after surgical anesthesia,just like lung barotrauma caused by mechanical ventilation,atelectasis and postoperative hypoxemia.AIM To investigate the effects of different positive end expiratory pressures(PEEPs)and tidal volumes(VTs)on respiratory function,the degree of the inflammatory response and hemodynamic indexes in patients undergoing surgery under general anesthesia.METHODS A total of 120 patients undergoing surgery for gastric or colon cancer under general anesthesia in Xinghua People's Hospital from January 2017 to January 2021 were randomly divided into Group A and Group B,with 60 cases in each group.The ventilation mode in Group A was VT(6.0 mL/kg)+PEEP(5.0 cmH_(2)O),while that in Group B was VT(6.0 mL/kg)+PEEP(8.0 cmH_(2)O).Blood gas parameters,respiratory mechanical parameters,inflammatory response indicators,hemodynamic indicators and related complications were compared between the two groups.RESULTS There were no significant differences in PaCO_(2),PaO_(2),oxygen or the examined indexes at T0 between group A and group B(P>0.05).The measured PaO_(2) value of patients in group A at T3 was higher than that in group B,and the difference was significant(P<0.05).There were no significant differences in peak airway pressure(P_(peak)),mean airway pressure or dynamic pulmonary compliance(Cdyn)at T0 between group A and group B(P>0.05).The measured P_(peak) value of patients in group A at T1 was higher than that in group B,and the difference was significant(P<0.05).The measured Cdyn value at T1 and T2 was greater than that in group B(P<0.05).Before surgery,there were no significant differences in tumor necrosis factor-α(TNF-α),interleukin(IL)-6 or IL-10 between group A and group B(P>0.05).After 4展开更多
基金supported by the Chinese Academy of Sciencesthe National Key R&D Program of China+22 种基金the CAS Center for Excellence in Particle PhysicsWuyi Universitythe Tsung-Dao Lee Institute of Shanghai Jiao Tong University in Chinathe Institut National de Physique Nucléaire et de Physique de Particules (IN2P3) in Francethe Istituto Nazionale di Fisica Nucleare (INFN) in Italythe Italian-Chinese collaborative research program MAECI-NSFCthe Fond de la Recherche Scientifique (F.R.S-FNRS)FWO under the "Excellence of Science-EOS" in Belgiumthe Conselho Nacional de Desenvolvimento Científico e Tecnològico in Brazilthe Agencia Nacional de Investigacion y Desarrollo in Chilethe Charles University Research Centrethe Ministry of Education,Youth,and Sports in Czech Republicthe Deutsche Forschungsgemeinschaft (DFG)the Helmholtz Associationthe Cluster of Excellence PRISMA+ in Germanythe Joint Institute of Nuclear Research (JINR)Lomonosov Moscow State University in Russiathe joint Russian Science Foundation (RSF)National Natural Science Foundation of China (NSFC) research programthe MOST and MOE in Taiwan,Chinathe Chulalongkorn UniversitySuranaree University of Technology in Thailandthe University of California at Irvine in USA
文摘The Jiangmen Underground Neutrino Observatory(JUNO)is a large liquid scintillator detector designed to explore many topics in fundamental physics.In this study,the potential of searching for proton decay in the p→νK^(+)mode with JUNO is investigated.The kaon and its decay particles feature a clear three-fold coincidence signature that results in a high efficiency for identification.Moreover,the excellent energy resolution of JUNO permits suppression of the sizable background caused by other delayed signals.Based on these advantages,the detection efficiency for the proton decay via p→νK^(+)is 36.9%±4.9%with a background level of 0.2±0.05(syst)±0.2(stat)events after 10 years of data collection.The estimated sensitivity based on 200 kton-years of exposure is 9.6×1033 years,which is competitive with the current best limits on the proton lifetime in this channel and complements the use of different detection technologies.
基金Foundation item: Project(PLN1129)supported by Opening Fund of State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation (Southwest Petroleum University), China
文摘To improve the understanding of the transport mechanism in shale gas reservoirs and build a theoretical basic for further researches on productivity evaluation and efficient exploitation, various gas transport mechanisms within a shale gas reservoir exploited by a horizontal well were thoroughly investigated, which took diffusion, adsorption/desorption and Darcy flow into account. The characteristics of diffusion in nano-scale pores in matrix and desorption on the matrix surface were both considered in the improved differential equations for seepage flow. By integrating the Langmuir isotherm desorption items into the new total dimensionless compression coefficient in matrix, the transport function and seepage flow could be formalized, simplified and consistent with the conventional form of diffusion equation. Furthermore, by utilizing the Laplace change and Sethfest inversion changes, the calculated results were obtained and further discussions indicated that transfer mechanisms were influenced by diffusion, adsorption/desorption. The research shows that when the matrix permeability is closed to magnitude of 10^-9D, the matrix flow only occurs near the surfacial matrix; as to the actual production, the central matrix blocks are barely involved in the production; the closer to the surface of matrix, the lower the pressure is and the more obvious the diffusion effect is; the behavior of adsorption/desorption can increase the matrix flow rate significantly and slow down the pressure of horizontal well obviously.
文摘BACKGROUND Mechanical ventilation can lead to the severe impairment of the metabolic pathway of alveolar surfactants,inactivating alveolar surfactants and significantly reducing lung-chest compliance.The cardiopulmonary function of elderly patients usually reduced to a certain extent,and there are lung complications after surgical anesthesia,just like lung barotrauma caused by mechanical ventilation,atelectasis and postoperative hypoxemia.AIM To investigate the effects of different positive end expiratory pressures(PEEPs)and tidal volumes(VTs)on respiratory function,the degree of the inflammatory response and hemodynamic indexes in patients undergoing surgery under general anesthesia.METHODS A total of 120 patients undergoing surgery for gastric or colon cancer under general anesthesia in Xinghua People's Hospital from January 2017 to January 2021 were randomly divided into Group A and Group B,with 60 cases in each group.The ventilation mode in Group A was VT(6.0 mL/kg)+PEEP(5.0 cmH_(2)O),while that in Group B was VT(6.0 mL/kg)+PEEP(8.0 cmH_(2)O).Blood gas parameters,respiratory mechanical parameters,inflammatory response indicators,hemodynamic indicators and related complications were compared between the two groups.RESULTS There were no significant differences in PaCO_(2),PaO_(2),oxygen or the examined indexes at T0 between group A and group B(P>0.05).The measured PaO_(2) value of patients in group A at T3 was higher than that in group B,and the difference was significant(P<0.05).There were no significant differences in peak airway pressure(P_(peak)),mean airway pressure or dynamic pulmonary compliance(Cdyn)at T0 between group A and group B(P>0.05).The measured P_(peak) value of patients in group A at T1 was higher than that in group B,and the difference was significant(P<0.05).The measured Cdyn value at T1 and T2 was greater than that in group B(P<0.05).Before surgery,there were no significant differences in tumor necrosis factor-α(TNF-α),interleukin(IL)-6 or IL-10 between group A and group B(P>0.05).After 4