In complex strata, oil-based drilling fluid is the preferred drilling fluid system, but its preparation cost is high, and there are hidden safety risks. Therefore, the new progress of high-performance anti-collapse wa...In complex strata, oil-based drilling fluid is the preferred drilling fluid system, but its preparation cost is high, and there are hidden safety risks. Therefore, the new progress of high-performance anti-collapse water-based drilling fluid at home and abroad is analyzed. It is difficult to prevent and control the well collapse. Once the well wall instability problem occurs, it will often bring huge economic losses to the enterprises, and the underground safety accidents will occur. In order to ensure the stability of the well wall and improve the downhole safety, the key treatment agent of water-based collapse drilling fluid is selected, the anti-collapse drilling fluid system is formulated, the evaluation method of drilling fluid prevention performance is established, and a set of water-based drilling fluid system suitable for easy to collapse strata in China is selected to ensure the downhole safety. The development trend of high performance anti-collapse water-based drilling fluid is expected to provide a reference for the research of high performance anti-collapse water-based drilling fluid system and key treatment agent.展开更多
In view of the shortcomings of poor temperature resistance, poor pumpability and poor pressure-bearing capacity of commonly used gel plugging materials, polyacrylamide (HPAM) and N,N-methylene bisacrylamide (BIS) were...In view of the shortcomings of poor temperature resistance, poor pumpability and poor pressure-bearing capacity of commonly used gel plugging materials, polyacrylamide (HPAM) and N,N-methylene bisacrylamide (BIS) were selected for crosslinking and compounding to make a new type of gel plugging material with high temperature and pressure resistance. The compressive strength and yield stress were measured by inverted observation method to evaluate the gel strength. The anti-temperature, anti-pressure, anti-dilution and gel-breaking properties of the gel were evaluated. Finally, 71 type high temperature and high pressure water loss instrument and high temperature and high pressure filter with slit plate were used to evaluate the plugging capacity of gel plugging agent. The experimental results show that the new gel plugging system between 100°C - 120°C, gelation time can be controlled at about 5 h;it has strong temperature resistance, compression resistance, dilution resistance and gel breaking performance. In the face of permeability and fracture leakage simulation experiments, when the ambient temperature below 120°C, pressure within 5 MPa, the filter loss of gel plugging agent is far less than the market two conventional plugging agent, has excellent plugging performance.展开更多
This project is explaining a laboratory development of a solid free drilling fluid formula that could be potentially used in tight gas reservoirs. The configuration of the weak gel fluid WGL-1, which is resistant to h...This project is explaining a laboratory development of a solid free drilling fluid formula that could be potentially used in tight gas reservoirs. The configuration of the weak gel fluid WGL-1, which is resistant to high temperature and high salt, was tested, and concluded that its gelling properties, salt and temperature resistance, and environmental protection were all in line with industry requirements. The final drilling fluid formula was developed as: water + (0.3% ~ 0.5%) NaOH + 5% KCl + 2% WGL-1 + 5% NaCl + (1.0% ~ 2.0%) HBFR Anti-high temperature fluid loss agent + 2% Polyol + (1.5% ~ 2.0%) SDL-1 Lubricant + 0.4% A4O1. The performance of the liquid was tested for temperature resistance, inhibition, gas formation protection effect, plugging performance, and static settlement stability. It was concluded that the temperature resistance performance is satisfied at 150°C, and the cuttings recovery rate is as high as 96.78%. It has good performance in inhibiting water dispersion and swelling of cuttings. The permeability recovery value reaches 88.9%, which meets the requirements of gas formation protection. The SSSI value shows that its settlement stability is good;under high temperature and high pressure, its sealing performance is good. This drilling fluid system has achieved the expected results and laid a foundation for further promoting the development of solid-free drilling fluid systems. The future development direction of solid-free drilling fluids is pointed out, to the improvement of properties to be applied in high temperature environment and have high salt resistance capacity.展开更多
文摘In complex strata, oil-based drilling fluid is the preferred drilling fluid system, but its preparation cost is high, and there are hidden safety risks. Therefore, the new progress of high-performance anti-collapse water-based drilling fluid at home and abroad is analyzed. It is difficult to prevent and control the well collapse. Once the well wall instability problem occurs, it will often bring huge economic losses to the enterprises, and the underground safety accidents will occur. In order to ensure the stability of the well wall and improve the downhole safety, the key treatment agent of water-based collapse drilling fluid is selected, the anti-collapse drilling fluid system is formulated, the evaluation method of drilling fluid prevention performance is established, and a set of water-based drilling fluid system suitable for easy to collapse strata in China is selected to ensure the downhole safety. The development trend of high performance anti-collapse water-based drilling fluid is expected to provide a reference for the research of high performance anti-collapse water-based drilling fluid system and key treatment agent.
文摘In view of the shortcomings of poor temperature resistance, poor pumpability and poor pressure-bearing capacity of commonly used gel plugging materials, polyacrylamide (HPAM) and N,N-methylene bisacrylamide (BIS) were selected for crosslinking and compounding to make a new type of gel plugging material with high temperature and pressure resistance. The compressive strength and yield stress were measured by inverted observation method to evaluate the gel strength. The anti-temperature, anti-pressure, anti-dilution and gel-breaking properties of the gel were evaluated. Finally, 71 type high temperature and high pressure water loss instrument and high temperature and high pressure filter with slit plate were used to evaluate the plugging capacity of gel plugging agent. The experimental results show that the new gel plugging system between 100°C - 120°C, gelation time can be controlled at about 5 h;it has strong temperature resistance, compression resistance, dilution resistance and gel breaking performance. In the face of permeability and fracture leakage simulation experiments, when the ambient temperature below 120°C, pressure within 5 MPa, the filter loss of gel plugging agent is far less than the market two conventional plugging agent, has excellent plugging performance.
文摘This project is explaining a laboratory development of a solid free drilling fluid formula that could be potentially used in tight gas reservoirs. The configuration of the weak gel fluid WGL-1, which is resistant to high temperature and high salt, was tested, and concluded that its gelling properties, salt and temperature resistance, and environmental protection were all in line with industry requirements. The final drilling fluid formula was developed as: water + (0.3% ~ 0.5%) NaOH + 5% KCl + 2% WGL-1 + 5% NaCl + (1.0% ~ 2.0%) HBFR Anti-high temperature fluid loss agent + 2% Polyol + (1.5% ~ 2.0%) SDL-1 Lubricant + 0.4% A4O1. The performance of the liquid was tested for temperature resistance, inhibition, gas formation protection effect, plugging performance, and static settlement stability. It was concluded that the temperature resistance performance is satisfied at 150°C, and the cuttings recovery rate is as high as 96.78%. It has good performance in inhibiting water dispersion and swelling of cuttings. The permeability recovery value reaches 88.9%, which meets the requirements of gas formation protection. The SSSI value shows that its settlement stability is good;under high temperature and high pressure, its sealing performance is good. This drilling fluid system has achieved the expected results and laid a foundation for further promoting the development of solid-free drilling fluid systems. The future development direction of solid-free drilling fluids is pointed out, to the improvement of properties to be applied in high temperature environment and have high salt resistance capacity.