Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixati...Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixation of tibial fracture. For each loading test under different configurations of UAEF, the ratio of the force-displacement was used to determine its stiffness value. The weakest mode of the UAEF device is in AP bending. Under each mode of compression,distraction , anteroposterial and lateral bending and torsion loading , increasing the pin number or pin diameter or pin separation, and/or reduction of pin group separation can significantly increase the stiffness values of UAEF (P<0.01). These data revealed that UAEF is suitable for the external fixation of tibial fracture.展开更多
This paper presents 5 patients with repeated recurrence of osteosarcoma (RROS). The primary focus of 3 patients were in the distal portion of femur, and 2 patients were in the proximal Portion of tibia. Three patients...This paper presents 5 patients with repeated recurrence of osteosarcoma (RROS). The primary focus of 3 patients were in the distal portion of femur, and 2 patients were in the proximal Portion of tibia. Three patients, whose chest X ray film were negative, were treated by amputation and chemotherapy. Two patients had isolated metastatic focus l. 5 cm in diameter in lung, were treated by amputation after 1 week of chemotherapy and then treated by lobectomy after 2 weeks of chemotherapy. After operation, the chemotherapy was carried out for 3 courses of treatment. The roentgenogram of chest and affected limb were taken once every two months. There were metastatic focuses found in the lung of 1 patient and in the distal portion of femur of 2 patients. One patient was operated on for 4 times. UP to now, 3 patients have been living for 5 yeara and 2 patients for 6 years after operation.展开更多
文摘Five fresh tibias removed from 30-40 years old dead males were osteotomized at one-third supra-medium segment and then fixed by an unilateral adjustable external fixator (UAEF) to be used as a model of external fixation of tibial fracture. For each loading test under different configurations of UAEF, the ratio of the force-displacement was used to determine its stiffness value. The weakest mode of the UAEF device is in AP bending. Under each mode of compression,distraction , anteroposterial and lateral bending and torsion loading , increasing the pin number or pin diameter or pin separation, and/or reduction of pin group separation can significantly increase the stiffness values of UAEF (P<0.01). These data revealed that UAEF is suitable for the external fixation of tibial fracture.
文摘This paper presents 5 patients with repeated recurrence of osteosarcoma (RROS). The primary focus of 3 patients were in the distal portion of femur, and 2 patients were in the proximal Portion of tibia. Three patients, whose chest X ray film were negative, were treated by amputation and chemotherapy. Two patients had isolated metastatic focus l. 5 cm in diameter in lung, were treated by amputation after 1 week of chemotherapy and then treated by lobectomy after 2 weeks of chemotherapy. After operation, the chemotherapy was carried out for 3 courses of treatment. The roentgenogram of chest and affected limb were taken once every two months. There were metastatic focuses found in the lung of 1 patient and in the distal portion of femur of 2 patients. One patient was operated on for 4 times. UP to now, 3 patients have been living for 5 yeara and 2 patients for 6 years after operation.