期刊文献+

Energy Characteristics of an Integrated Power Generation System with Photovoltaic and Fuel Cell

Energy Characteristics of an Integrated Power Generation System with Photovoltaic and Fuel Cell
下载PDF
导出
摘要 An integrated energy system (with photovoltaic (PV) and fuel cell (FC) for building) is proposed and assessed in term of its energy self-sufficiency rate in seven cities (Nagoya, Toyota, Tajimi, Takayama, Ogaki, Hamamatsu, Shizuoka) in Tokai region in Japan in this paper. In this work, it is considered that the electricity requirement of the building for household users is provided by a building integrated photovoltaic (BIPV) system and the gap between the energy demand and BIPV supply is fulfilled by the FC. The FC is powered by the electrolytic H2 produced when PV power was in surplus. Based on the study of applying the proposed system in seven cities, which clarifies the effectiveness of the integrated BIPV, electrolytic H2 and FC power generation system, a universal system model has been developed in this paper. It has been observed that the monthly power production from BIPV as well as FC system are higher in spring and summer, while they are both lower in autumn and winter at all considered locations. The self-sufficiency rate of the FC system is higher with decreasing households’ number and it has been observed that 16 is the most appropriate number of households in a building, whose electricity demand could be fully covered by the integrated PV and FC system. Due to its climate condition, Hamamatsu is the best city in the region for installing the proposed system. The correlation between the households’ number and self-sufficiency rate of the FC system per solar PV installation area can be expressed by the regression curve in the form of y = ax-b well. An integrated energy system (with photovoltaic (PV) and fuel cell (FC) for building) is proposed and assessed in term of its energy self-sufficiency rate in seven cities (Nagoya, Toyota, Tajimi, Takayama, Ogaki, Hamamatsu, Shizuoka) in Tokai region in Japan in this paper. In this work, it is considered that the electricity requirement of the building for household users is provided by a building integrated photovoltaic (BIPV) system and the gap between the energy demand and BIPV supply is fulfilled by the FC. The FC is powered by the electrolytic H2 produced when PV power was in surplus. Based on the study of applying the proposed system in seven cities, which clarifies the effectiveness of the integrated BIPV, electrolytic H2 and FC power generation system, a universal system model has been developed in this paper. It has been observed that the monthly power production from BIPV as well as FC system are higher in spring and summer, while they are both lower in autumn and winter at all considered locations. The self-sufficiency rate of the FC system is higher with decreasing households’ number and it has been observed that 16 is the most appropriate number of households in a building, whose electricity demand could be fully covered by the integrated PV and FC system. Due to its climate condition, Hamamatsu is the best city in the region for installing the proposed system. The correlation between the households’ number and self-sufficiency rate of the FC system per solar PV installation area can be expressed by the regression curve in the form of y = ax-b well.
出处 《Smart Grid and Renewable Energy》 2018年第4期57-73,共17页 智能电网与可再生能源(英文)
关键词 Smart Building Photovoltaics H2 Produced by Water ELECTROLYSIS Polymer ELECTROLYTE Fuel Cell SELF-SUFFICIENCY Rate Smart Building Photovoltaics H2 Produced by Water Electrolysis Polymer Electrolyte Fuel Cell Self-Sufficiency Rate
  • 相关文献

参考文献1

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部