期刊文献+

Sludge Density Prediction in a Wastewater Chemical Coagulation Process

Sludge Density Prediction in a Wastewater Chemical Coagulation Process
下载PDF
导出
摘要 This paper reports an approach to estimate the sludge density in a physicochemical treatment of municipal wastewater, experiments considered 4 coagulants (aluminum sulfate SAl, iron sulfate SFe, aluminum polychloride PAX, iron polychloride PIX), and 2 flocculant products (cationic CP and anionic AP polymers). Experimental approach is based on running a set of jar tests at different coagulant concentrations. After the stirring and resting times took place, pH and conductivity were registered finding that SAl and SFe either with or without polymers are the coagulants producing the higher pH drop. Conductivity measures also establish two kind of data since higher conductivity (about 2000 ) was observed for SAl, and PIX, PIX + CP, PIX + AP;otherwise a conductivity about 1300 was observed for SAl + PC, SFe and PAX alone and with CP or AP. Settleable solids (SST) determined with an Imhoff cone were similar for sulfates and polychlorides, but dry sludge (DS) clearly set up two groups the one with higher sludge content corresponds to sulfates group. The quotient of DS divided by the SST provided an estimation of the apparent sludge density, in this way it was observed that higher densities were obtained for sludge from sulfates at lower coagulant concentrations;also sludge from SFe was heavier than the one from SAl. Otherwise, polychlorides produced a lighter sludge in respect to the one obtained with sulfates, and between them the PIX coagulant provided a heavier sludge than the PAX coagulant. This paper reports an approach to estimate the sludge density in a physicochemical treatment of municipal wastewater, experiments considered 4 coagulants (aluminum sulfate SAl, iron sulfate SFe, aluminum polychloride PAX, iron polychloride PIX), and 2 flocculant products (cationic CP and anionic AP polymers). Experimental approach is based on running a set of jar tests at different coagulant concentrations. After the stirring and resting times took place, pH and conductivity were registered finding that SAl and SFe either with or without polymers are the coagulants producing the higher pH drop. Conductivity measures also establish two kind of data since higher conductivity (about 2000 ) was observed for SAl, and PIX, PIX + CP, PIX + AP;otherwise a conductivity about 1300 was observed for SAl + PC, SFe and PAX alone and with CP or AP. Settleable solids (SST) determined with an Imhoff cone were similar for sulfates and polychlorides, but dry sludge (DS) clearly set up two groups the one with higher sludge content corresponds to sulfates group. The quotient of DS divided by the SST provided an estimation of the apparent sludge density, in this way it was observed that higher densities were obtained for sludge from sulfates at lower coagulant concentrations;also sludge from SFe was heavier than the one from SAl. Otherwise, polychlorides produced a lighter sludge in respect to the one obtained with sulfates, and between them the PIX coagulant provided a heavier sludge than the PAX coagulant.
出处 《Journal of Water Resource and Protection》 2013年第7期1-4,共4页 水资源与保护(英文)
关键词 COAGULANT FLOCCULANT WASTEWATER Treatment SLUDGE DENSITY Coagulant Flocculant Wastewater Treatment Sludge Density
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部