Performances of a Bitumen Fume and Condensate Generation System for Sampling Method Development

Performances of a Bitumen Fume and Condensate Generation System for Sampling Method Development
下载PDF
导出
摘要 A laboratory system was designed to generate bitumen fumes and expose tested samplers in a homogenised chamber. The system was also designed to condense the fumes in the form of oil that could be used as a standard for further analytical method development. The laboratory system was evaluated in terms of stability, repeatability, aging, and ranges, focusing on the quality and quantity of the fumes and their physical characteristics. The fumes generated with the laboratory system were also compared to fumes emitted at workplaces to evaluate their similarity. The results demonstrated that laboratory fume generation was stable and repeatable. Humidity ranged from 20% to 80% RH and the total fume concentration ranged from 0.01 to 9.36 mg.m<sup>-3</sup>, covering the conditions encountered for road paving worksites. The fumes generated in the laboratory were found to be similar to those of workplaces, with slight differences in light compounds equivalent to C12 and below n-alkanes. Thus, the system designed in this study is considered capable of generating bitumen fumes used to develop sampling and analysis methods. A laboratory system was designed to generate bitumen fumes and expose tested samplers in a homogenised chamber. The system was also designed to condense the fumes in the form of oil that could be used as a standard for further analytical method development. The laboratory system was evaluated in terms of stability, repeatability, aging, and ranges, focusing on the quality and quantity of the fumes and their physical characteristics. The fumes generated with the laboratory system were also compared to fumes emitted at workplaces to evaluate their similarity. The results demonstrated that laboratory fume generation was stable and repeatable. Humidity ranged from 20% to 80% RH and the total fume concentration ranged from 0.01 to 9.36 mg.m<sup>-3</sup>, covering the conditions encountered for road paving worksites. The fumes generated in the laboratory were found to be similar to those of workplaces, with slight differences in light compounds equivalent to C12 and below n-alkanes. Thus, the system designed in this study is considered capable of generating bitumen fumes used to develop sampling and analysis methods.
作者 Benjamin Sutter Eric Pelletier Christel Ravera Eddy Langlois Benjamin Sutter;Eric Pelletier;Christel Ravera;Eddy Langlois(Pollutants Metrology, Institut National de Recherche et Sécurité, Vandoeuvre-Les-Nancy, France)
机构地区 Pollutants Metrology
出处 《Journal of Environmental Protection》 2016年第7期973-984,共12页 环境保护(英文)
关键词 BITUMEN FUMES Laboratory Generation Condensate Generation Road Paving Bitumen Fumes Laboratory Generation Condensate Generation Road Paving
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部