期刊文献+

Experimental Study of Filling Ratio Effect on the Thermal Performance in a Multi-Heat Pipe with Graphene Oxide/Water Nanofluids 被引量:2

Experimental Study of Filling Ratio Effect on the Thermal Performance in a Multi-Heat Pipe with Graphene Oxide/Water Nanofluids
下载PDF
导出
摘要 This experimental study is performed to investigate heat transfer performance of a multi-heat pipe cooling device in the condition of different filling ratios (40%, 60%, 80% and 100%) and different constant heat fluxes (10 - 30 W). Here, pure water (distilled water) and graphene oxide (GO)/water nanofluids are employed respectively as working fluid. GO/water nanofluids were synthesized by the modified Hummers method with 0.05%, 0.10%, 0.15%, and 0.20% volume concentrations. Multi-heat pipe is fabricated from copper;the heating and cooling sections are the same size and both are connected by four circular parallel tubes. Temperature fields and thermal resistance are measured for different filling ratio, heat fluxes and volume concentrations. The results indicated that the thermal performance of heat pipe increased with increasing the concentration of GO nanoparticles in the base fluid, while the maximum heat transfer enhancement was observed at 0.20% volume concentration. GO/water nanofluids showed lower thermal resistance compared to pure water;the optimal thermal resistance was obtained at 100% filling charge ratio with 0.20% volume concentration. Studies were also demonstrated that heat transfer coefficient of the heat pipe significantly increases with increasing the input heat flux and GO nanoparticles concentration. This experimental study is performed to investigate heat transfer performance of a multi-heat pipe cooling device in the condition of different filling ratios (40%, 60%, 80% and 100%) and different constant heat fluxes (10 - 30 W). Here, pure water (distilled water) and graphene oxide (GO)/water nanofluids are employed respectively as working fluid. GO/water nanofluids were synthesized by the modified Hummers method with 0.05%, 0.10%, 0.15%, and 0.20% volume concentrations. Multi-heat pipe is fabricated from copper;the heating and cooling sections are the same size and both are connected by four circular parallel tubes. Temperature fields and thermal resistance are measured for different filling ratio, heat fluxes and volume concentrations. The results indicated that the thermal performance of heat pipe increased with increasing the concentration of GO nanoparticles in the base fluid, while the maximum heat transfer enhancement was observed at 0.20% volume concentration. GO/water nanofluids showed lower thermal resistance compared to pure water;the optimal thermal resistance was obtained at 100% filling charge ratio with 0.20% volume concentration. Studies were also demonstrated that heat transfer coefficient of the heat pipe significantly increases with increasing the input heat flux and GO nanoparticles concentration.
作者 Mohamed Salem Tarek A. Meakhail Magdy A. Bassily Shuichi Torii Mohamed Salem;Tarek A. Meakhail;Magdy A. Bassily;Shuichi Torii(Department of Mechanical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, Egypt;Graduate School of Science and Technology, Kumamoto University, Kumamoto, Japan;Department of Mechanical Engineering, Faculty of Engineering, Minia University, Minia, Egypt)
出处 《World Journal of Nano Science and Engineering》 2016年第4期153-164,共12页 纳米科学与工程(英文)
关键词 Multi-Heat Pipe Graphene Oxide Filling Ratio Volume Fraction Thermal Resistance Multi-Heat Pipe Graphene Oxide Filling Ratio Volume Fraction Thermal Resistance
  • 相关文献

同被引文献7

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部