期刊文献+

The Effect of Direct Gas Fluorination on Medical Grade Poly(methyl methacrylate)

The Effect of Direct Gas Fluorination on Medical Grade Poly(methyl methacrylate)
下载PDF
导出
摘要 Medical-grade poly(methyl methacrylate) (PMMA) is extensively employed in the fabrication of a variety of medical implants, including intraocular lenses (IOLs). However, a postoperative complication that leads to the failure of the implanted intraocular lenses has been recently identified. This process, termed calcification, occurs when calcium-containing deposits accumulate on the surface of the IOL. In this study direct gas fluorination was used to modify the surface of PMMA in an attempt to increase the service lifetime of the material in optical applications. PMMA discs exposed to a 20% fluorine/nitrogen gas mixture for 24 h were compared with untreated PMMA discs serving as control samples. Over time, both surface-fluorinated and untreated PMMA samples immersed in a simulated aqueous humour solution (SAHS) (pH 7.4, 35°C) were used to carry out in vitro studies. Attenuated total refractive Infrared spectroscopy (ATR-IR) Scanning electron microscopy (SEM), coupled with Energy dispersive X-ray analysis (EDX), showed that calcium-containing surface deposits were less abundant on surface-fluorinated PMMA compared with the control samples, indicating that the fluorinated surface was acting as a barrier to the deposits. Gravimetric analysis data showed that the decreased rate of diffusion compared with that of a control sample was due to the fluorinated surface. Medical-grade poly(methyl methacrylate) (PMMA) is extensively employed in the fabrication of a variety of medical implants, including intraocular lenses (IOLs). However, a postoperative complication that leads to the failure of the implanted intraocular lenses has been recently identified. This process, termed calcification, occurs when calcium-containing deposits accumulate on the surface of the IOL. In this study direct gas fluorination was used to modify the surface of PMMA in an attempt to increase the service lifetime of the material in optical applications. PMMA discs exposed to a 20% fluorine/nitrogen gas mixture for 24 h were compared with untreated PMMA discs serving as control samples. Over time, both surface-fluorinated and untreated PMMA samples immersed in a simulated aqueous humour solution (SAHS) (pH 7.4, 35°C) were used to carry out in vitro studies. Attenuated total refractive Infrared spectroscopy (ATR-IR) Scanning electron microscopy (SEM), coupled with Energy dispersive X-ray analysis (EDX), showed that calcium-containing surface deposits were less abundant on surface-fluorinated PMMA compared with the control samples, indicating that the fluorinated surface was acting as a barrier to the deposits. Gravimetric analysis data showed that the decreased rate of diffusion compared with that of a control sample was due to the fluorinated surface.
出处 《Open Journal of Organic Polymer Materials》 2014年第4期74-83,共10页 有机高分子材料期刊(英文)
关键词 Poly(methyl methacrylate) (PMMA) Surface FLUORINATION In VITRO Studies Simulated Aqueous HUMOUR Solution (SAHS) Medical Polymers Poly(methyl methacrylate) (PMMA) Surface Fluorination In Vitro Studies Simulated Aqueous Humour Solution (SAHS) Medical Polymers
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部