期刊文献+

Optimization and Comparisons for Separation, Detection and Quantification of 12 Aminoglycosides Using 2 Chromatographic Conditions by LC-MS/MS 被引量:1

Optimization and Comparisons for Separation, Detection and Quantification of 12 Aminoglycosides Using 2 Chromatographic Conditions by LC-MS/MS
下载PDF
导出
摘要 Aminoglycosides are a family of antibiotics with important applications in veterinary medicine. Their ionic character, the similarity structures and the high polarity due to the presence of two or more amino and hydroxyl groups cause a difficulty in separation and make these compounds poorly retained on the reversed phase column. An analytical method for the separation and detection of 12 aminoglycosides has been optimized using two kinds of chromatographic conditions (HILIC, Ion pairing). In Hydrophilic Interaction, ZIC_HILIC column was used, by which the following parameters for the mobile phase were evaluated: concentration of ammonium acetate buffer, percentage of formic acid and effect of acid type. The maximum and adequate concentration of ammonium acetate for the majority of analytes was set to 30 mM. The percentage 0.1% of formic acid increases the response for the majority of analytes. On the other side, the use of 0.1% of trifluoroacetic acid improves the response when compared with the response obtained with 0.1% of formic acid except for Spectinomycin Dihydrostreptomycin and Streptomycin. For ion pairing chromatography, the concentration of pentafluoropropionic acid was tested and the greatest value appeared to be 9.2 mM. Therefore, the comparison between the two separation methods shows that the response area of the majority of analytes tested increases when using the ion pair mode. Also, the high value of S/N and the lower detection limit (5 - 15 μg m·L﹣1 for most aminoglycosides studied make the ion pairing method more preferable than HILIC interaction. Aminoglycosides are a family of antibiotics with important applications in veterinary medicine. Their ionic character, the similarity structures and the high polarity due to the presence of two or more amino and hydroxyl groups cause a difficulty in separation and make these compounds poorly retained on the reversed phase column. An analytical method for the separation and detection of 12 aminoglycosides has been optimized using two kinds of chromatographic conditions (HILIC, Ion pairing). In Hydrophilic Interaction, ZIC_HILIC column was used, by which the following parameters for the mobile phase were evaluated: concentration of ammonium acetate buffer, percentage of formic acid and effect of acid type. The maximum and adequate concentration of ammonium acetate for the majority of analytes was set to 30 mM. The percentage 0.1% of formic acid increases the response for the majority of analytes. On the other side, the use of 0.1% of trifluoroacetic acid improves the response when compared with the response obtained with 0.1% of formic acid except for Spectinomycin Dihydrostreptomycin and Streptomycin. For ion pairing chromatography, the concentration of pentafluoropropionic acid was tested and the greatest value appeared to be 9.2 mM. Therefore, the comparison between the two separation methods shows that the response area of the majority of analytes tested increases when using the ion pair mode. Also, the high value of S/N and the lower detection limit (5 - 15 μg m·L﹣1 for most aminoglycosides studied make the ion pairing method more preferable than HILIC interaction.
出处 《American Journal of Analytical Chemistry》 2014年第14期982-994,共13页 美国分析化学(英文)
关键词 AMINOGLYCOSIDES ION PAIRING ZIC-HILIC LC-MS/MS Aminoglycosides Ion Pairing ZIC-HILIC LC-MS/MS
  • 相关文献

同被引文献7

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部