期刊文献+

Adaptive Match-Filtering: A Biomedical Application to Identify T-Wave Alternans

Adaptive Match-Filtering: A Biomedical Application to Identify T-Wave Alternans
下载PDF
导出
摘要 T-wave alternans (TWA), consisting in an alternation of the electrocardiographic (ECG) repolarization segment (T-wave), is a promising index of the risk of sudden cardiac death. By definition, it is characterized by a frequency component, termed fTWA, that matches half heart rate. The heart-rate adaptive match filter (AMF) based method is a technique for automatic TWA identification from the digital ECG. Aim of the present study was to provide a complete technical description of the filter able to explain its methodological principles. The AMF is usually realized as a 6th order Butterworth filter with a narrow (0.12 Hz) passing band centered in fTWA. It is applied in a bidirectional fashion, so that final filtering order is 12. While extracting the TWA component, the AMF simultaneously filters out every ECG component including noise and artefacts, and thus results are very robust. Goodness of the technique was tested using 8 synthetic ECG tracings corrupted by typical noisy factors, such as white random noise, baseline wanderings, heart-rate variability, and others. Six ECG tracings were affected by 100 μV TWA, whereas two were not. Results indicate that the AMF-based method is able to prevent false-positive and false-negative detections and, thus, represents a useful tool for a reliable TWA identification. T-wave alternans (TWA), consisting in an alternation of the electrocardiographic (ECG) repolarization segment (T-wave), is a promising index of the risk of sudden cardiac death. By definition, it is characterized by a frequency component, termed fTWA, that matches half heart rate. The heart-rate adaptive match filter (AMF) based method is a technique for automatic TWA identification from the digital ECG. Aim of the present study was to provide a complete technical description of the filter able to explain its methodological principles. The AMF is usually realized as a 6th order Butterworth filter with a narrow (0.12 Hz) passing band centered in fTWA. It is applied in a bidirectional fashion, so that final filtering order is 12. While extracting the TWA component, the AMF simultaneously filters out every ECG component including noise and artefacts, and thus results are very robust. Goodness of the technique was tested using 8 synthetic ECG tracings corrupted by typical noisy factors, such as white random noise, baseline wanderings, heart-rate variability, and others. Six ECG tracings were affected by 100 μV TWA, whereas two were not. Results indicate that the AMF-based method is able to prevent false-positive and false-negative detections and, thus, represents a useful tool for a reliable TWA identification.
出处 《Natural Science》 2014年第10期709-718,共10页 自然科学期刊(英文)
关键词 ADAPTIVE FILTERING Digital ECG T-WAVE ALTERNANS SUDDEN Cardiac DEATH Adaptive Filtering Digital ECG T-Wave Alternans Sudden Cardiac Death
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部