Mechanical response of uterine tissue under the influence of hemostatic clips: A non-linear finite-element approach

Mechanical response of uterine tissue under the influence of hemostatic clips: A non-linear finite-element approach
下载PDF
导出
摘要 A modeling strategy to predict the ability of surgical clips to achieve mechanical hemostasis when applied to the cut edge of a thick and muscular tissue is presented in this work. Although such a model may have broad utility in the design of hemostatic clips and other surgical and wound closure applications, our particular focus was on uterine closure following a Cesarean delivery. Mechanical closure of a blood vessel, which is the first step in the hemostatic process, is established when the compressive forces on the outer surface of a blood vessel are sufficient to overcome the local blood pressure and collapse the vessel. For thick tissue, forces applied to the tissue surface set up a stress distribution within the tissue that, if sufficient to mechanically close all vessels, will lead to cessation of local blood flow. The focus of the current work was on utilization of a planar and nonlinear finite element model to predict the pressure distribution within uterine tissue under the influence of hemostatic clips. After experimental model validation with a polymer tissue phantom, design curves were numerically developed, which consisted of the clip force necessary to achieve hemostasis for a given thickness tissue as well as the resulting deformed tissue thickness. Such curves could form the basis for a preliminary clip design, which would provide initial design guidance before more expensive experimental studies were required. A modeling strategy to predict the ability of surgical clips to achieve mechanical hemostasis when applied to the cut edge of a thick and muscular tissue is presented in this work. Although such a model may have broad utility in the design of hemostatic clips and other surgical and wound closure applications, our particular focus was on uterine closure following a Cesarean delivery. Mechanical closure of a blood vessel, which is the first step in the hemostatic process, is established when the compressive forces on the outer surface of a blood vessel are sufficient to overcome the local blood pressure and collapse the vessel. For thick tissue, forces applied to the tissue surface set up a stress distribution within the tissue that, if sufficient to mechanically close all vessels, will lead to cessation of local blood flow. The focus of the current work was on utilization of a planar and nonlinear finite element model to predict the pressure distribution within uterine tissue under the influence of hemostatic clips. After experimental model validation with a polymer tissue phantom, design curves were numerically developed, which consisted of the clip force necessary to achieve hemostasis for a given thickness tissue as well as the resulting deformed tissue thickness. Such curves could form the basis for a preliminary clip design, which would provide initial design guidance before more expensive experimental studies were required.
出处 《Journal of Biomedical Science and Engineering》 2013年第12期21-28,共8页 生物医学工程(英文)
关键词 Medical Device Design HEMOSTASIS FINITE Element MODELING TISSUE MODELING Myometrial TISSUE Medical Device Design Hemostasis Finite Element Modeling Tissue Modeling Myometrial Tissue
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部