期刊文献+

Control Rod Calibration and Worth Calculation for Optimized Power Reactor 1000 (OPR-1000) Using Core Simulator OPR1000

Control Rod Calibration and Worth Calculation for Optimized Power Reactor 1000 (OPR-1000) Using Core Simulator OPR1000
下载PDF
导出
摘要 Control rod is used to change the power in nuclear reactor.?Certainly, the core at any moment can be made subcritical condition and shut downs when occurring?to emergency instance in the core. The rod is grouped based?on their function and located at different places in the core where their feature is maximized.?Two methods of control rod calibration are the asymptotic period method and the rod-drop method, which were applied in this experiment. In the first method, the reactor is made supcritical by inserting the control rod to be calibrated a certain level. The rod drop method is to determine the subcritical;at the critical state, the rod to be calibrated is dropped into the core, and the resulting decay of neutron flux is observed and related to the reactivity. In this paper, the regulating rod will be calibrated according to the reactivity in OPR-1000 that corresponds to a certain control rod insert or withdraw, and the reactivity in power reactor depends?on the integral and differential control rod group too. The core simulator OPR1000 is used to test those methods. Control rod is used to change the power in nuclear reactor.?Certainly, the core at any moment can be made subcritical condition and shut downs when occurring?to emergency instance in the core. The rod is grouped based?on their function and located at different places in the core where their feature is maximized.?Two methods of control rod calibration are the asymptotic period method and the rod-drop method, which were applied in this experiment. In the first method, the reactor is made supcritical by inserting the control rod to be calibrated a certain level. The rod drop method is to determine the subcritical;at the critical state, the rod to be calibrated is dropped into the core, and the resulting decay of neutron flux is observed and related to the reactivity. In this paper, the regulating rod will be calibrated according to the reactivity in OPR-1000 that corresponds to a certain control rod insert or withdraw, and the reactivity in power reactor depends?on the integral and differential control rod group too. The core simulator OPR1000 is used to test those methods.
出处 《World Journal of Nuclear Science and Technology》 2017年第1期15-23,共9页 核科学与技术国际期刊(英文)
关键词 Control ROD The ASYMPTOTIC Period METHOD The Rod-Drop METHOD CORE SIMULATOR OPR1000 Control Rod The Asymptotic Period Method The Rod-Drop Method Core Simulator OPR1000
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部