期刊文献+

Comparison between Distractor Application on Both Radial &Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

Comparison between Distractor Application on Both Radial &Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture
下载PDF
导出
摘要 Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically. A key method of surgical fixation is external fixation by distractor. Distractor can be applied either only on the radial side or on both ulnar and radial sides. Materials and Methods: A prospective randomized and comparative study of 1 year duration was conducted on 32 patients admitted in the Department of Orthopaedics of BSMC & H in the age group of 20 to 75 years old with AO types B and C distal radius fracture along with involvement of the ulnar styloid process. The parameters studied were restoration of radial length, restoration of radial angle, intracarpal step-off and palmar tilt which were statistically evaluated and Fisher’s exact test was performed. The two tailed P-value was calculated and both the groups were statistically compared. Results: In our study, 37.5% patients in Group A and 81.25% in Group B had a radial difference Table 1, Chart 1). 43.75% patients in Group A and 87.5% in Group B had radial angle Table 2, Chart 2). 31.25% in Group A and 75% had intra carpal step off Table 3, Chart 3). 62.5% had an abnormal palmar tilt in Group A while only 6.25% had an abnormal palmar tilt in Group B which is extremely statistically significant. On an average, 2 mm of distraction was required in 75% patients of Group A while only 30% patients in Group B required distraction (Table 4, Chart 4). Conclusion: In our study, the radial difference, radial angle, intra carpal step off and palmar tilt returned significantly to normal in the patients treated with distractor on radial side only when compared with distractor application on both radial and ulnar sides for distal radius fracture with ulnar styloid process involvement. Also post-operative distraction required under image intensifier was higher in the group treated with distractor on either side than those with distractor only on radial Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically. A key method of surgical fixation is external fixation by distractor. Distractor can be applied either only on the radial side or on both ulnar and radial sides. Materials and Methods: A prospective randomized and comparative study of 1 year duration was conducted on 32 patients admitted in the Department of Orthopaedics of BSMC & H in the age group of 20 to 75 years old with AO types B and C distal radius fracture along with involvement of the ulnar styloid process. The parameters studied were restoration of radial length, restoration of radial angle, intracarpal step-off and palmar tilt which were statistically evaluated and Fisher’s exact test was performed. The two tailed P-value was calculated and both the groups were statistically compared. Results: In our study, 37.5% patients in Group A and 81.25% in Group B had a radial difference Table 1, Chart 1). 43.75% patients in Group A and 87.5% in Group B had radial angle Table 2, Chart 2). 31.25% in Group A and 75% had intra carpal step off Table 3, Chart 3). 62.5% had an abnormal palmar tilt in Group A while only 6.25% had an abnormal palmar tilt in Group B which is extremely statistically significant. On an average, 2 mm of distraction was required in 75% patients of Group A while only 30% patients in Group B required distraction (Table 4, Chart 4). Conclusion: In our study, the radial difference, radial angle, intra carpal step off and palmar tilt returned significantly to normal in the patients treated with distractor on radial side only when compared with distractor application on both radial and ulnar sides for distal radius fracture with ulnar styloid process involvement. Also post-operative distraction required under image intensifier was higher in the group treated with distractor on either side than those with distractor only on radial
出处 《Open Journal of Orthopedics》 2013年第5期227-233,共7页 矫形学期刊(英文)
关键词 FRACTURE Distal Radius Plaster Cast DISTRACTOR RADIAL Length RADIAL Angle Intra Carpal Step Off PALMAR Tilt Fischer’s Test P-Value Fracture Distal Radius Plaster Cast Distractor Radial Length Radial Angle Intra Carpal Step Off Palmar Tilt Fischer’s Test P-Value
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部