期刊文献+

Can We Predict Menorrhagia with Intrauterine Contraceptive Device (IUCD) Insertion?

Can We Predict Menorrhagia with Intrauterine Contraceptive Device (IUCD) Insertion?
下载PDF
导出
摘要 Objective: Studying sub endometrial vascularity and blood flow in cases using intrauterine contraceptive devices for contraception with and without menorrhagia compared to cases not using intrauterine contraceptive devices. Methods: Three hundred and fifteen women attending gynecology and family planning outpatient clinics in the maternity hospital, Ain Shams University were included in the study. They were classified into three groups, 105 women using IUCD with menorrhagia (group I), 105 women using IUCD without menorrhagia (group II), and 105 normal controls not using IUCD (group III). After excluding local causes for bleeding, blood disease or any medical disorders, transvaginal ultrasound including three dimensional power Doppler (3DPD) ultrasound was done for all women. Right and left uterine artery pulsatility index (PI) and resistance index (RI) were calculated, subednometrial blood flow RI and PI were obtained then 3DPD Vascular indices (VI, FI and VFI) of subendometrial blood flow were obtained for all cases. Statistical analysis was done to compare between the three groups. Results: A significant statistical difference was found as regards subendometrial vascularity indices, while there was no difference as regards bilateral uterine arteries Doppler indices in the three groups. Conclusion: Subendometrial vascularity in cases of menorrhagia with IUCD was markedly higher than in cases without menorrhagia and cases with no IUCD. 3DPD may be used for selection of cases prior to insertion of IUCD. Objective: Studying sub endometrial vascularity and blood flow in cases using intrauterine contraceptive devices for contraception with and without menorrhagia compared to cases not using intrauterine contraceptive devices. Methods: Three hundred and fifteen women attending gynecology and family planning outpatient clinics in the maternity hospital, Ain Shams University were included in the study. They were classified into three groups, 105 women using IUCD with menorrhagia (group I), 105 women using IUCD without menorrhagia (group II), and 105 normal controls not using IUCD (group III). After excluding local causes for bleeding, blood disease or any medical disorders, transvaginal ultrasound including three dimensional power Doppler (3DPD) ultrasound was done for all women. Right and left uterine artery pulsatility index (PI) and resistance index (RI) were calculated, subednometrial blood flow RI and PI were obtained then 3DPD Vascular indices (VI, FI and VFI) of subendometrial blood flow were obtained for all cases. Statistical analysis was done to compare between the three groups. Results: A significant statistical difference was found as regards subendometrial vascularity indices, while there was no difference as regards bilateral uterine arteries Doppler indices in the three groups. Conclusion: Subendometrial vascularity in cases of menorrhagia with IUCD was markedly higher than in cases without menorrhagia and cases with no IUCD. 3DPD may be used for selection of cases prior to insertion of IUCD.
出处 《Open Journal of Obstetrics and Gynecology》 2017年第7期753-766,共14页 妇产科期刊(英文)
关键词 INTRAUTERINE CONTRACEPTIVE Devices IUCD 3D Power DOPPLER Ultrasound MENORRHAGIA Intrauterine Contraceptive Devices IUCD 3D Power Doppler Ultrasound Menorrhagia
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部