期刊文献+

The diagnostic accuracy of the usage of the <i>Fetal Medicine Foundation</i>’s (FMF) on-line risk calculator with first-trimester ultrasound for screening for preeclampsia in high-risk pregnant Brazilian population

The diagnostic accuracy of the usage of the <i>Fetal Medicine Foundation</i>’s (FMF) on-line risk calculator with first-trimester ultrasound for screening for preeclampsia in high-risk pregnant Brazilian population
下载PDF
导出
摘要 To evaluate the sensitivity and specificity of the usage of the FMF On-Line Risk Calculator with first-trimester ultrasound, in screening assessment for preeclampsia (PE), without serum markers. To define the best risk cut-off values for early, intermediate and late preeclampsia. Diagnostic accuracy study of pregnant women who had first-trimester ultrasounds between 11 and 13 weeks. The index test was the first-trimester ultrasound scan plus the FMF On-Line Risk Calculator to assess the risk for PE. The reference standard was the confirmation of actual development of early, intermediate or late PE. For calculations of sensitivity and specificity to determine the best cut-off values for early, intermediate and late PE, all the information was processed into ROC curves. The assessment of preeclampsia risk in the first trimester using an ultrasound plus the FMF On-Line Risk Calculator demonstrated a significant (p < 0.05) area under the ROC curve for early, intermediate and late preeclampsia. The best risk cut-off values were defined as 2.1% for early, 2.5% for intermediate and 3.5% for late preeclampsia. The first trimester US plus the FMF On-Line Risk Calculator tool was useful and applicable when assessing the risk for preeclampsia in a specific pregnant Brazilian population. To evaluate the sensitivity and specificity of the usage of the FMF On-Line Risk Calculator with first-trimester ultrasound, in screening assessment for preeclampsia (PE), without serum markers. To define the best risk cut-off values for early, intermediate and late preeclampsia. Diagnostic accuracy study of pregnant women who had first-trimester ultrasounds between 11 and 13 weeks. The index test was the first-trimester ultrasound scan plus the FMF On-Line Risk Calculator to assess the risk for PE. The reference standard was the confirmation of actual development of early, intermediate or late PE. For calculations of sensitivity and specificity to determine the best cut-off values for early, intermediate and late PE, all the information was processed into ROC curves. The assessment of preeclampsia risk in the first trimester using an ultrasound plus the FMF On-Line Risk Calculator demonstrated a significant (p < 0.05) area under the ROC curve for early, intermediate and late preeclampsia. The best risk cut-off values were defined as 2.1% for early, 2.5% for intermediate and 3.5% for late preeclampsia. The first trimester US plus the FMF On-Line Risk Calculator tool was useful and applicable when assessing the risk for preeclampsia in a specific pregnant Brazilian population.
机构地区 Faculty of Medicine
出处 《Open Journal of Obstetrics and Gynecology》 2012年第3期298-303,共6页 妇产科期刊(英文)
关键词 Accuracy Sensitivity Specificity PREECLAMPSIA First Trimester RISK Accuracy Sensitivity Specificity Preeclampsia First Trimester Risk
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部