Effects of water flow volume on the isolation of bacteria from motion sensor faucets

Effects of water flow volume on the isolation of bacteria from motion sensor faucets
下载PDF
导出
摘要 Water outlets for washing hands and medical equipment are essential for preventing hospital infection. The present study clarified the effects of water flow volume on the identification and quantitative evaluation of bacteria found around spouts in the 17 hand-washing stations. Pseu-domonas aeruginosa was detected from 4 sta-tions before adjustment and 2 after adjustment. Although no significant difference was identified in the detection rate of P. aeruginosa (p = 0.368), when combining P. aeruginosa and glucose non-fermentative Gram-negative bacilli (NFB), the number of stations with P. aeruginosa and/or NFB decreased significantly from 15 before adjustment to 9 after adjustment (p = 0.023). Before adjust-ment, quantity of bacteria was “2+” for 3 stations and “1+” for 7 stations, but was “1+” for 3 stations and “2+” for 0 stations after adjustment. These results show that quantity of bacteria could be reduced from spouts by adjusting flow volume. These results were also supported by experiments for cleanliness using Adenosine 5’-triphosphate bioluminescence me- thod. Water outlets for washing hands and medical equipment are essential for preventing hospital infection. The present study clarified the effects of water flow volume on the identification and quantitative evaluation of bacteria found around spouts in the 17 hand-washing stations. Pseu-domonas aeruginosa was detected from 4 sta-tions before adjustment and 2 after adjustment. Although no significant difference was identified in the detection rate of P. aeruginosa (p = 0.368), when combining P. aeruginosa and glucose non-fermentative Gram-negative bacilli (NFB), the number of stations with P. aeruginosa and/or NFB decreased significantly from 15 before adjustment to 9 after adjustment (p = 0.023). Before adjust-ment, quantity of bacteria was “2+” for 3 stations and “1+” for 7 stations, but was “1+” for 3 stations and “2+” for 0 stations after adjustment. These results show that quantity of bacteria could be reduced from spouts by adjusting flow volume. These results were also supported by experiments for cleanliness using Adenosine 5’-triphosphate bioluminescence me- thod.
机构地区 不详
出处 《Health》 2011年第3期146-150,共5页 健康(英文)
关键词 INFECTION Control Water Flow VOLUME MOTION SENSOR Faucets Infection Control Water Flow Volume Motion Sensor Faucets
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部