期刊文献+

流动注射标准加入法测定尿铬方法的研究

STUDY ON THE METNOD OF DETERMINATION OF CHROMIUM IN THE URINE BY FLOWINJECTION STANDARD ADDITION METHOD
下载PDF
导出
摘要 研究了用Cr(Ⅵ)-二苯碳酰二胼体系测定尿液中微量铬的流动注射标准加入法,处理后的含铬试样作载流,Cr(Ⅵ)标准液从进样阀加入载流中。工作曲线和样品测定条件完全一致,消除了未知基体的干扰。分析结果的变异系数为1.73%~3.66%,加标回收率为97.2%~106.0%. This paper presents a methed of determination of chromium in the urine withflowinJection standard addition methed for the reaction between Cr(Ⅵ)and l,5-diphenylcarbazlueis studied.The treated sample is used as stream. The sta ndard solution of Cr(Ⅵ)is injected fromthe sample valve. The relative standard deviation is 1.73%~3.66%and the recovery rate ofchromium is 97.2%~106.0%.The current system has a simple,rapid,accurate feature and nu-merous potential applications for qua ntitative studies of trace analysis of chromium in the en viron-mental sample.
出处 《重庆建筑工程学院学报》 CSCD 1994年第1期47-51,共5页
关键词 流动注射标准加入法 尿铬 二苯碳酰二胼 环境保护 flowinjection standard addition method,chromium in the urine,1.5-diphenylcarbazide,environmental protection
  • 相关文献

参考文献2

  • 1张帆.二苯卡巴肼比色法测定尿铬方法的探讨[J]工业卫生与职业病,1987(01). 被引量:1
  • 2王立军,章申.离子交换法分离和富集水中微量Cr(Ⅲ)及Cr(Ⅵ)的研究[J]环境科学,1981(02). 被引量:1

相关作者