期刊文献+

电站锅炉喷水减温器的检验与热疲劳裂纹 被引量:4

Inspection and Thermal Fatigue Cracking of Spray Desuperheater for Power Plant Boiler
下载PDF
导出
摘要 介绍了喷水减温器的工作原理和优缺点及结构形式,用实例对3台电站锅炉喷水减温器的定期检验及检验中发现的热疲劳问题进行了分析,说明了热疲劳是喷水减温器破坏的主要形式之一,强调了喷水减温器定期检验的重要性。 In this paper, the working principle, strong and weak points, structure type of spray type Desuperheater have been introduced simply. The periodical inspection on spray type desuperheaters of three electricity power plant boilers and the thermal fatigue problems found in inspection process have been intro- duced and analyzed with living examples. It is explained that the thermal fatigue is one of the important kinds of failures of spray type desuperheater. The importance of the periodical inspection on spray type desuperheater has been emphasized.
出处 《中国锅炉压力容器安全》 2004年第3期22-25,共4页 China Boiler and Pressure Vessel Safety
关键词 电站锅炉 喷水减温器 热疲劳裂纹 定期检验 Spray type desuperheater periodical inspection Thermal fatigue