期刊文献+

大亚湾核电站辐射防护和最优化(ALARA)管理体系十年的实践和经验 被引量:13

PRACTICE AND EXPERIENCE OF RADIATION PROTECTION AND OPTIMIZATION (ALARA) MANAGEMENT SYSTEM IN DAYA BAY NPP DURING THE PAST 10 YEARS
下载PDF
导出
摘要 大亚湾核电站在近 1 0年的安全运行实践中建立并不断完善了以“全员培训、全体参与、全过程管理”为基本内容的辐射防护和最优化 (ALARA)管理体系 ,同时在“基础结构 (infrastructure)”上下功夫 ,努力构筑该体系有效运作的平台。本文综合介绍了大亚湾核电站辐射防护和最优化管理体系的内容和特点及其有效实施的基本经验。为了有效实施这一管理体系 ,核电站必须加强辐射防护责任制和辐射防护人员的主导作用 ,尤其是在高辐射风险作业中的技术支持和监督作用 ;必须强调该体系与核电站安全运行管理体系的有机结合和积极互动 ;必须重视安全文化建设 ,坚持经验反馈和透明度 。 With the practice of 10 years safe operation, Daya Bay Nuclear Power Station has established and continuously improved the management system for radiation protection and optimization (ALARA ) which contains 3 basic requirements: all workers are trained, all employees are engaged in totally, and work management is implemented for the whole process.At the same time,strong efforts have been made to build the“infrastructure” as a platform for its effective operation. This article introduces the contents and characteristics of the system and basic experiences of its effective implementation. In order to implement the management system effectively,it is necessary for NPPs to strengthen the responsibility system for radiation protection and the leading role of the radiation protection personnel, especially the role of technical support and supervision during the work with high radiation risk, emphasize the organic combination and actively mutual action with the safe operation management system of the plant, and pay great attention to the formation of safety culture and the experience feedback to ensure the continuous improvement of the management system. (
出处 《辐射防护》 CAS CSCD 北大核心 2004年第3期131-143,共13页 Radiation Protection
关键词 大亚湾核电站 辐射防护 最优化 管理体系 基础结构 安全文化 Radiation Protection,Optimization(ALARA),Management System,Infrastructure,Safety Culture)
  • 相关文献

参考文献10

二级参考文献14

  • 1STI/HARSHAW User's Manual.TLD Radiation Evaluation and Management System (TLD-REMS).1992 被引量:1
  • 2STI/HARSHAW User's Manual.Dose Calculation Algorithm for the Department of Energy Laboratory Accreditation Program (DOELAP).1992 被引量:1
  • 3CANBERRA User's Manual.Code for Internal Dosimetry (CINDY).1992 被引量:1
  • 4Optimization of Radiation Protection and Organization of Unit Outages at the CLINTON,KOEBERG,PHILIPPSBURG and RINGHALS Nuclear Power Plants.CEPN Report No.223 被引量:1
  • 5晏仲民 杨茂春.核电站工作管理[M].北京:原子能出版社,1999.. 被引量:1
  • 6夏益华.辐射防护最优化及其应用(第三章)[M].北京:原子能出版社,2000.. 被引量:1
  • 7.大亚湾核电站程序.C-IP/HPS/220,ALARA实施管理[Z].,.. 被引量:1
  • 8.大亚湾核电站程序.C-IP/HP3/214,高辐射区进入和高辐射风险作业管理[Z].,.. 被引量:1
  • 9UNSCEAR 冷瑞平 等译.潘自强总审校.电离辐射源与效应[A].冷瑞平,等译.潘自强总审校.联合国原子辐射效应科学委员(UNSCEAR)2000年向联合国大会提交的报告及科学附件[C].太原:山西科学技术出版社,2000,附件E,表7.. 被引量:1
  • 10杨茂春,陈德淦.广东大亚湾核电站辐射防护与最优化(ALARA)管理体系及其初步实践[J].辐射防护,2000,20(3):129-138. 被引量:5