期刊文献+

两种方差在铷原子频标长稳测量中的比较分析 被引量:2

Comparison of Two Variances in the Long Time Frequency Stability Measurement of R_b Atomic Frequency Standard
下载PDF
导出
摘要 人们通常用阿仑方差 (AllanVariance)来表征原子频标的频率稳定度。在国外 ,测量铷原子频标长期频率稳定度时 ,除采用阿仑方差外 ,也通常运用哈达玛方差 (HadamardVariance)进行表征。本文简要介绍了哈达玛方差和阿仑方差 ,以及两种方差在铷原子频标日频率稳定度测试中的具体应用 ,并对测量结果进行了比较分析。 Allan Variance usually be used to express frequency staility of atomic frequency standard. Excluding Allan Variance, Hadamard Variance usually be used to do the same at external. This paper summarily introduces both Allan Variance and Hadamard Variance. And two kind of Variances have been applied in the concrete to measure frequency stability with one day sample time of R b Atomic frequency standard. The compare analysis of measurement results has also been made.
出处 《宇航计测技术》 CSCD 2004年第1期40-42,共3页 Journal of Astronautic Metrology and Measurement
关键词 铷原子频标 频率稳定度 阿仑方差 哈达玛方差 频率漂移率 +Hadamard Variance Allan Variance Atomic frequency standard Measurement result
  • 相关文献

参考文献2

  • 1.时间频率,计量测试技术手册[M].中国计量出版社,No.11(1).. 被引量:1
  • 2.时间频率计量计量培训教材[M].原子能出版社,2003.. 被引量:1