期刊文献+

一种动态自校正超声液位测量方法 被引量:1

一种动态自校正超声液位测量方法
下载PDF
导出
摘要 相对于传统静态超声液位测量技术 ,介绍一种新的超声液位测量方法 ,通过采用特殊的液面约束管装置 ,从原理上实现了液面动态和速度自校正。由于引入了这些校正装置 ,超声波回波信号变得相对复杂了 ,因而在硬件电路和软件上使用高频全采样来分析和处理回波信号 ,最终达到动态高精度液位测量。 Inthe traditionalliquid depth measures technology bythe ultrasonic is static. As the contrast, the method in the ultrasonicliquid depth measure,introduced in this text, is dynamic. Through adopting the special device to retrain and manage liquid, it has solved the liquid trendingand speed correctingby oneself from the measuring principle. Because has introduced these correcting devices, the signal of ultrasonic echo waves becomes relatively complicated. Therefore use high frequency to sample completely in the circuit of hardware and software, come to analyze and deal with the echo signal, and finallycan measure the liquid depth dynamicand high accuracy.
作者 廖雁鸿
出处 《港口装卸》 2004年第1期14-16,共3页 Port Operation
关键词 超声波 液位测量 自校正 全采样 回波信号 测量传感装置 测量原理 信号分析处理仪 ultrasonic wave liquid depth measure dynamic correct by oneself sample completely
  • 相关文献

参考文献5

  • 1张福学编著..现代实用传感器电路[M].北京:中国计量出版社,1997:441.
  • 2李朝青编著..单片机原理及接口技术 简明修订版[M].北京:北京航空航天大学出版社,1999:290.
  • 3陈桂生编著..超声换能器设计[M].北京:海洋出版社,1984:387.
  • 4同济大学声学教研室.超声工业测量技术[M].上海:上海人民出版社,1977.. 被引量:6
  • 5苗德霖.超声波测液位技术及液位声速的修正[M].北京:铁道技术出版社,2000.. 被引量:1