期刊文献+

Contrast-enhanced harmonic endoscopic ultrasound imaging: Basic principles, present situation and future perspectives 被引量:8

Contrast-enhanced harmonic endoscopic ultrasound imaging: Basic principles, present situation and future perspectives
下载PDF
导出
摘要 Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a greyscale with optimal contrast and spatial resolution. Recent technological advances made contrast harmonic technology available for endoscopic ultrasound(EUS) for the first time in 2008. Thus, the evaluation of microcirculation is now feasible with EUS, prompting the evolution of contrast-enhanced EUS from vascular imaging to images of the perfused tissue. Although the relevant experience is still preliminary, several reports have highlighted contrast-enhanced harmonic EUS(CHEUS) as a promising noninvasive method to visualise and characterise lesions and to differentiate benign from malignant focal lesions. Even if histology remains the gold standard, the combination of CH-EUS and EUS fine needle aspiration(EUS-FNA) can not only render EUS more accurate but may also assist physicians inmaking decisions when EUS-FNA is inconclusive,increasing the yield of EUS-FNA by guiding the puncture with simultaneous imaging of the vascularity.The development of CH-EUS has also opened up exciting possibilities in other research areas,including monitoring responses to anticancer chemotherapy or to ethanolinduced pancreatic tissue ablation,anticancer therapies based on ultrasound-triggered drug and gene delivery,and therapeutic adjuvants by contrast ultrasound-induced apoptosis.Contrast harmonic imaging is gaining popularity because of its efficacy,simplicity and noninvasive nature,and many expectations are currently resting on this technique.If its potential is confirmed in the near future,contrast harmonic imaging will become a standard practice in EUS. Over the last decade, the development of stabilised microbubble contrast agents and improvements in available ultrasonic equipment, such as harmonic imaging, have enabled us to display microbubble enhancements on a greyscale with optimal contrast and spatial resolution. Recent technological advances made contrast harmonic technology available for endoscopic ultrasound (EUS) for the first time in 2008. Thus, the evaluation of microcirculation is now feasible with EUS, prompting the evolution of contrast-enhanced EUS from vascular imaging to images of the perfused tissue. Although the relevant experience is still preliminary, several reports have highlighted contrast-enhanced harmonic EUS (CH-EUS) as a promising noninvasive method to visualise and characterise lesions and to differentiate benign from malignant focal lesions. Even if histology remains the gold standard, the combination of CH-EUS and EUS fine needle aspiration (EUS-FNA) can not only render EUS more accurate but may also assist physicians in making decisions when EUS-FNA is inconclusive, increasing the yield of EUS-FNA by guiding the puncture with simultaneous imaging of the vascularity. The development of CH-EUS has also opened up exciting possibilities in other research areas, including monitoring responses to anticancer chemotherapy or to ethanol-induced pancreatic tissue ablation, anticancer therapies based on ultrasound-triggered drug and gene delivery, and therapeutic adjuvants by contrast ultrasound-induced apoptosis. Contrast harmonic imaging is gaining popularity because of its efficacy, simplicity and non-invasive nature, and many expectations are currently resting on this technique. If its potential is confirmed in the near future, contrast harmonic imaging will become a standard practice in EUS.
出处 《World Journal of Gastroenterology》 SCIE CAS 2014年第42期15549-15563,共15页 世界胃肠病学杂志(英文版)
  • 相关文献

参考文献11

  • 1Atsushi Sofuni,Takao Itoi,Fumihide Itokawa,Takayoshi Tsuchiya,Toshio Kurihara,Kentaro Ishii,Syujiro Tsuji,Nobuhito Ikeuchi,Fuminori Moriyasu.Usefulness of contrast-enhanced ultrasonography in determining treatment efficacy and outcome after pancreatic cancer chemotherapy[J].World Journal of Gastroenterology,2008,14(47):7183-7191. 被引量:3
  • 2Jun-Ho Choi,Dong-Wan Seo,Joon Hyuk Choi,Do Hyun Park,Sang Soo Lee,Sung Koo Lee,Myung-Hwan Kim.Utility of contrast-enhanced harmonic EUS in the diagnosis of malignant gallbladder polyps (with videos)[J].Gastrointestinal Endoscopy.2013 被引量:1
  • 3Chan Hyuk Park,Moon Jae Chung,Tak Geun Oh,Jeong Youp Park,Seungmin Bang,Seung Woo Park,Hyunki Kim,Ho Kyoung Hwang,Woo Jung Lee,Si Young Song.Differential diagnosis between gallbladder adenomas and cholesterol polyps on contrast-enhanced harmonic endoscopic ultrasonography[J].Surgical Endoscopy.2013(4) 被引量:1
  • 4Klaus Kannengiesser,Reiner Mahlke,Frauke Petersen,Anja Peters,Matthias Ross,Torsten Kucharzik,Christian Maaser.Contrast-enhanced harmonic endoscopic ultrasound is able to discriminate benign submucosal lesions from gastrointestinal stromal tumors[J].Scandinavian Journal of Gastroenterology.2012(12) 被引量:3
  • 5Ahmed Alzaraa,Gianpiero Gravante,Wen Yuan Chung,Dhya Al-Leswas,Morgan Bruno,Ashley R. Dennison,David M. Lloyd.Targeted microbubbles in the experimental and clinical setting[J].The American Journal of Surgery.2012(3) 被引量:1
  • 6Hiroo Imazu,Keisuke Kanazawa,Naoki Mori,Keiichi Ikeda,Hiroshi Kakutani,Kazuki Sumiyama,Shoryoku Hino,Tiing Leong Ang,Salem Omar,Hisao Tajiri.Novel quantitative perfusion analysis with contrast-enhanced harmonic EUS for differentiation of autoimmune pancreatitis from pancreatic carcinoma[J].Scandinavian Journal of Gastroenterology.2012(7) 被引量:1
  • 7Masao Tanaka,Carlos Fernández-del Castillo,Volkan Adsay,Suresh Chari,Massimo Falconi,Jin-Young Jang,Wataru Kimura,Philippe Levy,Martha Bishop Pitman,C. Max Schmidt,Michio Shimizu,Christopher L. Wolfgang,Koji Yamaguchi,Kenji Yamao.International consensus guidelines 2012 for the management of IPMN and MCN of the pancreas[J]. Pancreatology . 2012 (3) 被引量:13
  • 8A. S?ftoiu,C. Dietrich,P. Vilmann.Contrast-enhanced harmonic endoscopic ultrasound[J].Endoscopy.2012(06) 被引量:2
  • 9Ning Zhong,Lizhi Zhang,Naoki Takahashi,Vladislav Shalmiyev,Marcia Irene Canto,Jonathan E. Clain,John C. Deutsch,John DeWitt,Mohamad A. Eloubeidi,Ferga C. Gleeson,Michael J. Levy,Shawn Mallery,Massimo Raimondo,Elizabeth Rajan,Tyler Stevens,Mark Topazian.Histologic and Imaging Features of Mural Nodules in Mucinous Pancreatic Cysts[J].Clinical Gastroenterology and Hepatology.2012(2) 被引量:2
  • 10Fabian Kiessling,Jessica Bzyl,Stanley Fokong,Monica Siepmann,Georg Schmitz,Moritz Palmowski.Targeted Ultrasound Imaging of Cancer: An Emerging Technology on its Way to Clinics[J].Current Pharmaceutical Design.2012(15) 被引量:1

二级参考文献22

  • 1[1]World Health Organization.The world health report.WHO 2000 被引量:1
  • 2[2]Hansen R,Quebbeman E,Ritch P,Chitambar C,Anderson T.Continuous 5-fluorouracil (5FU) infusion in carcinoma of the pancreas:a phase Ⅱ study.Am J Med Sci 1988; 295:91-93 被引量:1
  • 3[3]Kovach JS,Moertel CG,Schutt AJ,Hahn RG,Reitemeier RJ.Proceedings:A controlled study of combined 1,3-bis-(2-chloroethyl)-1-nitrosourea and 5-fluorouracil therapy for advanced gastric and pancreatic cancer.Cancer 1974; 33:563-567 被引量:1
  • 4[4]Wiggans RG,Woolley PV,Macdonald JS,Smythe T,Ueno W,Schein PS.Phase Ⅱ trial of streptozotocin,mitomycin-C and 5-fluorouracil (SMF) in the treatment of advanced pancreatic cancer.Cancer 1978; 41:387-391 被引量:1
  • 5[5]Evans TR,Lofts FJ,Mansi JL,Glees JP,Dalgleish AG,Knight MJ.A phase Ⅱ study of continuous-infusion 5-fluorouracil with cisplatin and epirubicin in inoperable pancreatic cancer.Br J Cancer 1996; 73:1260-1264 被引量:1
  • 6[6]Rothman H,Cantrell JE Jr,Lokich J,Difino S,Harvey J,Ahlgren J,Fryer J.Continuous infusion 5-fluorouracil plus weekly cisplatin for pancreatic carcinoma.A Mid-Atlantic Oncology Program study.Cancer 1991; 68:264-268 被引量:1
  • 7[7]Crown J,Casper ES,Botet J,Murray P,Kelsen DP.Lack of efficacy of high-dose leucovorin and fluorouracil in patients with advanced pancreatic adenocarcinoma,J Clin Oncol 1991; 9:1682-1986 被引量:1
  • 8[8]Moertel CG,Frytak S,Hahn RG,O'Connell MJ,Reitemeier RJ,Rubin J,Schutt AJ,Weiland LH,Childs DS,Holbrook MA,Lavin PT,Livstone E,Spiro H,Knowlton A,Kalser M,Barkin J,Lessner H,Mann-Kaplan R,Ramming K,Douglas HO Jr,Thomas P,Nave H,Bateman J,Lokich J,Brooks J,Chaffey J,Corson JM,Zamcheck N,Novak JW.Therapy of locally unresectable pancreatic carcinoma:a randomized comparison of high dose (6000 rads) radiation alone,moderate dose radiation (4000 rads + 5-fluorouracil),and high dose radiation + 5-fluorouracil:The Gastrointestinal Tumor Study Group.Cancer 1981; 48:1705-1710 被引量:1
  • 9[9]Gastrointestinal Tumor Study Group.Treatment of locally unresectable carcinoma of the pancreas:comparison of combined-modality therapy (chemotherapy plus radiotherapy) to chemotherapy alone.J Natl Cancer Inst 1988; 80:751-755 被引量:1
  • 10[10]Klaassen DJ,Maclntyre JM,Catton GE,Engstrom PF,Moertel CG.Treatment of locally unresectable cancer of the stomach and pancreas:a randomized comparison of 5-fluorouracil alone with radiation plus concurrent and maintenance 5-fluorouracil--an Eastern Cooperative Oncology Group study.J Clin Oncol 1985; 3:373-378 被引量:1

共引文献16

同被引文献39

引证文献8

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部