结合空调循环分析了非共沸HCs/阻燃剂混合工质的泄漏特性,包括一定泄漏率下引起最大组成变化的泄漏点和工质相态、泄漏率-总组成变化关系、泄漏引起的组成变化对HCs/阻燃剂混合工质安全性与循环性能的影响分析。
The leakage related issues were investigated for the non-azeotropic HC/Fire-suppressant mixtures in air-conditioning cycles, and the changes in the composition, flammability, and cycle performance of the mixtures with the leakage ratio were analyzed.
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
2004年第1期17-20,共4页
Journal of Engineering Thermophysics
基金
国家科学基金(No.59976025)
关键词
HCs/阻燃剂混合工质
泄漏
安全性
循环性能
HC/fire-suppressant mixtures
leakage
safety
performances in air-conditioning cycles