摘要 应用三维稳态热工水力软件GENEPI,对CPR1000蒸汽发生器管束区及汽水分离器区域进行热工水力分析,得到了管束区和汽水分离器入口的热工水力参数分布。结果表明,汽水分离器区域的负荷不均匀性明显,中间及热侧的汽水分离器承受的负荷较高,分析数据为汽水分离器及干燥器湿度分析提供输入数据和设计依据。对比了不同汽水分离器局部阻力系数下的结果,表明汽水分离器局部阻力系数对其负荷不均匀性有一定的影响,系数越大,流量越均匀。 The steady thermal-hydraulic analysis for tube-bundle region including primary separators of CPR1000 steam generator was done by three-dimensional software GENEPI.The results show the flow mal-distribution of the tube-bundle and primary separator regions,and the primary separators in the central and hot side bear a larger load.The analysis can be used as the input of the moisture analysis of separators and dryers.The calculation results of different local pressure-drop coefficients of the primary separator were also compared.The results show that the larger the coefficient is,the more uniform the flow distribution is.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2014年第S1期326-329,共4页 Atomic Energy Science and Technology
关键词 蒸汽发生器 汽水分离器 负荷不均匀性 GENEPI steam generator primary separator flow mal-distribution GENEPI
  • 相关文献

参考文献1

  • 1广东核电培训中心编..900 MW压水堆核电站系统与设备 下[M].北京:原子能出版社,2005:611.