摘要
文章简要介绍了速差法DN100mm小口径超声波气体流量计的原理、性能,利用涡轮流量计进行标定的原理、过程及测量结果。表明DN100mm超声波气体流量计在0.35m/s~14m/s的流速范围内的均方误差可达到±1.1%。
The principles and characteristics of the DN100mm ultrasonic gas flowmeter based on a velocity difference method are introduced in this paper. The principles, procedures and results of its calibration with respect to a standard turbine flowmeter are also presented.
出处
《声学技术》
CSCD
2003年第4期230-232,共3页
Technical Acoustics