期刊文献+

LiCl溶液换热器的设计与实验研究

Design and experiment study of LiCl solution heat exchanger
下载PDF
导出
摘要 本文基于套管式换热器的一般设计过程,阐述了LiCl溶液套管式换热器螺旋管长度的计算方法,并通过换热器实验研究了传热系数增强值的范围。对于采用螺旋管的套管式换热器,其传热管长度是通过光管的扭转长度系数以及传热系数增强值进行修正的。 The length calculation method of helical coiled tube in LiCl solution heat exchanger was expounded in this article based on the general design process of double-pipe heat exchanger, and the range of heat transfer coefficient enhancement value was studied by the heat exchanger experiment For doublepipe heat exchanger with helical coiled tube, the length of the heat transfer tube is updated by the torsion length coefficient of tube and the enhancement value of heat transfer coefficient
作者 王凌杰 岳岭
出处 《电子测试》 2017年第9X期37-39,共3页 Electronic Test
关键词 LiCl溶液 套管式换热器 螺旋管 LiCl solution double-pipe heat exchanger helical coiled tube
  • 相关文献

参考文献4

  • 1吴业正主编..小型制冷装置设计指导[M].北京:机械工业出版社,1999:383.
  • 2余建祖编著..换热器原理与设计[M].北京:北京航空航天大学出版社,2006:265.
  • 3王凌杰,岳岭.LiCl溶液除湿空调再生性能的实验研究[J].电子测试,2016,27(10):117-119. 被引量:3
  • 4史美中,王中铮,李新国编著..热交换器原理与设计 第5版[M].南京:东南大学出版社,2014:311.