期刊文献+

土中自由场应力与结构表面压力测量的差异 被引量:7

The difference between measurements of stress in soil and pressure on wall-surface
下载PDF
导出
摘要 在土木工程试验测量中,往往把土中自由场应力传感器与结构表面压力传感器不加区分,互相代用。本文给出了这两类情况下传感器匹配误差的定量计算公式,详细阐明了两类传感器在设计原则、测量误差计算方法、误差范围、应力场分布状态和扰动范围等方面的差异,以期克服土中应力和压力测量的盲目性。 Usually the transducers are indiscriminately used to measure stress in soil and pressure on wallsurface in civil engineering test. The formulae of matcherror in these two circumstances are derived and the differences in design principles, computing methods and ranges of error, stress field and disturbed zone of these two kinds of transducer are expounded in this paper.The purpose is to avoid the incorrect use of transducers in measurement of stress in soil and pressure on wallsurface.
作者 余尚江 曾辉
出处 《岩土工程学报》 EI CAS CSCD 北大核心 2003年第6期684-687,共4页 Chinese Journal of Geotechnical Engineering
关键词 土木工程 匹配 应力传感器 压力传感器 土木试验 stress pressure transducer match-error
  • 相关文献

参考文献3

二级参考文献23

  • 1曾辉,李欢钬.压电式结构表面压力传感器匹配问题理论与试验研究[J].防护工程,1996(3):22-41. 被引量:5
  • 2曾辉.传感器与岩土介质相互作用研究综述[J].防护工程,1990,(2):30-37. 被引量:2
  • 3第二冶金建设研究所技术情报室.国外静土压盒理论与实践研究综述[M].,1997.. 被引量:1
  • 4中国人民解放军工程兵司令部.非弹性介质压力测量(译文集)[M].,1974.. 被引量:1
  • 5侯岳衡.圆柱式应力传感器匹配误差的理论研究[M].洛阳总参工程兵科研三所、计量院,1981.. 被引量:1
  • 6俞儒一 安春春.土应力传感器动力匹配问题初探[J].岩土工程学报,1988,(6):38-47. 被引量:1
  • 7曾辉.土应力传感器动匹配问题野外化爆试验研究报告[M].洛阳总参工程兵科研三所,1995.. 被引量:1
  • 8曾辉.结构表面压力测试技术研究报告[M].洛阳总参工程兵科研三所,1993.. 被引量:1
  • 9侯岳衡.圆柱式应力传感器匹配误差的试验研究[M].洛阳总参工程兵科研三所、计量院,1981.. 被引量:1
  • 10侯岳衡,防护工程,1980年,3期 被引量:1