PV-10型真空压电阀门性能测定实验 被引量:2

Performance measurement experiment of PV-10 piezoelectric valve
下载PDF
导出
摘要 压电晶体阀是真空充气系统中一种微流量充气阀门。它具有流量小、开启快、可以远程控制等优点,但压电阀门的进气量难以用函数的方式准确描述,而且随着使用时间的增长往往有改变。本文介绍了一种PV 10型阀门的性能测定方法和结果,为HT 7托卡马克聚变装置中性束注入器系统离子源和中性化室充气量确定提供了参考数据。 Piezoelectric valve is often applied to vacuum aerating system as a micro-adjustable charge valve. It has many merits, such as little flux, fast start-up, remote control, etc. But gas throughput of this kind of valve is difficult to be confirmed accurately and easy to change while usage. This article mainly discusses performance measurement method of PV-10 valve, and provides references for ion source and neutralizer aerating system of HT-7 tokamak neutral beam injector system.
出处 《真空》 CAS 北大核心 2003年第6期34-36,共3页 Vacuum
关键词 真空压电阀门 真空充气系统 托卡马克聚变装置 中性束注入器系统 等离子体 piezoelectric valve pulse power supply, vacuum measurement neutral beam injector
  • 相关文献

参考文献6

  • 1郭鸿震主编..真空系统设计与计算[M].北京:冶金工业出版社,1986:255.
  • 2张华顺主编,万春侯等编著..离子源和大功率中性束源[M].北京:原子能出版社,1987:555.
  • 3石秉人.磁约束聚变原理与实践[M].北京:原子能出版社,1999.192-197. 被引量:2
  • 4A罗思.真空技术[M].北京:机械工业出版社,1980.256-258. 被引量:1
  • 5孙孟大.一种处于高电位而在地电位控制的稳压电源[A]..第12届全国电源技术论文集[C].,.. 被引量:1
  • 6Schilling G,Ashcroft D,L. Neutral Beam Injection On the PLT Tokamak[C]. Engineering Problems of Fusion Research, 1979,1379- 1382. 被引量:1