期刊文献+

核子水分—密度仪现场标定试验

Experimental Study on Field Calibration of Nuclear Moisture-Density Meter
下载PDF
导出
摘要 核子水分—密度仪是快速无损检测新设备 ,当前现场标定的误差校正方法有时偏差非常大 ,影响仪器的正常使用。针对现场标定中存在的问题 ,根据现场标定试验成果 ,采用数值分析方法 ,提出了几种适合校正砂土材料的分段偏差校正法、二次曲线法、二次曲面法以及线性校正法等误差校正方法 ,并通过对比分析 。 Nuclear moisture-density meter is a new kind of quick and no-damage instrument. Currently, its field calibration has great errors therefore its normal application is affected. Aiming at the problems existing in the field calibration, and according to the experimental results of field calibration, numerical analysis method is adopted. Several error revision methods such as subsection, conic, conicoid, and linear method and so on, are proposed, which are suited for sand and soil material. And, the best calibration method is presented through contrast and comparison among the methods.
出处 《中国农村水利水电》 北大核心 2003年第11期55-58,共4页 China Rural Water and Hydropower
关键词 核子水分——密度仪 误差校正 二次曲面 线性校正法 nuclear moisture-density meter field calibration, error revision, conicoid
  • 相关文献

参考文献3

  • 1张志涌等编著..精通MATLAB[M].北京:北京航空航天大学出版社,2000:547.
  • 2中华人民共和国水利部.SL275—2001核子一水分密度仪现场测试规程[S].北京:中国水利水电出版社,2002.. 被引量:1
  • 3中华人民共和国建设部.GBJ123—88土工试验方法标准[S].北京:中国计划出版社,1988.. 被引量:1