为验证双目立体视觉中的摄像机标定的精度,对常用的标定法进行分析。在双目立体视觉中,相机参数获取结果的准确性直接影响到系统结果的准确性,研究基于MATLAB和OPENCV双目相机标定获得摄像机的参数。实验结果表明:基于OPENCV的标定精度比基于MATLAB标定精度更高,误差更小。
In an attempt to verify the accuracy of camera calibration in binocular stereo vision,common calibration methods were analyzed.Calibration experiments were performed on MATLAB and OPENCV software using experimental methods.The results show that the calibration accuracy based on OPENCV is higher than that based on MATLAB.This experiment provides a reference for the research of camera calibration method.