分析漳泽发电厂K—215—130—1型汽轮机热耗大、经济性差的原因,通过低压缸技术改造,在额定工况下可降低整机热耗率约282.9kJ/kW·h,可降低煤耗率约10.3kg/kW·h,较大地提高了汽轮机的经济性。
It analysis the cause of bigger heat consumption and poorer efficient performance of turbine model K-215-130-1 in Zhangze Power Plant.Through the technical modernization of LPturbine,to reduce the heat consumption rate about 282.9 kg/kW·h of full machine in rated power,and to reduce the coal consumption rate about 10.3 g/kW·h,at the same time highly improved the efficiency performance of turbine.
出处
《山西电力》
2003年第A01期9-12,共4页
Shanxi Electric Power