到目前为止还没有哪一种单一措施能彻底有效地解决超长墙体结构裂缝控制问题,本文介绍了在超长墙体施工中,采取在长墙净高的中段设置"离散型水平暗梁"有效控制墙体有害裂缝的施工方法,以期与业内同行进行交流。
So far have not a single measure can effectively solve the problem of super-long wall structure crack control,this paper introduces the super-long wall,in the construction of the take is set in the middle of the wall clear height of'discrete levels of dark beam'effective control of the construction method of harmful cracks,in order to communicate with industry peers.
出处
《施工技术》
CAS
北大核心
2017年第S1期286-288,共3页
Construction Technology
关键词
离散型水平暗梁
超长墙体
裂缝控制
检测
discrete level of dark beam
super-long wall
crack control
detection