期刊文献+

酒店节水系统工程设计与应用 被引量:6

Design and application of water saving system engineering in hotel
下载PDF
导出
摘要 根据大连香格里拉酒店水系统原设计用水量和市节水办要求的节水目标 ,针对酒店的可利用场地 ,提出了中水回用MBR系统和蒸汽凝结水回收系统的合并设计方案 ,同时在所有用水终端加装节水器控制用水量。应用一年多节水效果显著 ,实现了节水目标。 According to municipal water saving policy and hotel original design water consumption volume, a engineering combining secondary water reuse MBR system with steam condensing water reuse system was put into practice in existing site and one certain water saving unit is installed in all water pipe terminals in Dalian Shangrila hotel. The project has been operated perfectly for one year and realizes water saving target. The design and application study result of this water saving system engineering can be extended.
机构地区 大连理工大学
出处 《能源工程》 2003年第4期59-62,共4页 Energy Engineering
关键词 酒店 节水系统 工程设计 中水回用 膜生物反应器 蒸汽凝结水回用 终端节水器 hotel water saving system engineering secondary water reuse membrane bio\|reactor(MBR) steam condensing water reuse terminal water saving unit