根据大连香格里拉酒店水系统原设计用水量和市节水办要求的节水目标 ,针对酒店的可利用场地 ,提出了中水回用MBR系统和蒸汽凝结水回收系统的合并设计方案 ,同时在所有用水终端加装节水器控制用水量。应用一年多节水效果显著 ,实现了节水目标。
According to municipal water saving policy and hotel original design water consumption volume, a engineering combining secondary water reuse MBR system with steam condensing water reuse system was put into practice in existing site and one certain water saving unit is installed in all water pipe terminals in Dalian Shangrila hotel. The project has been operated perfectly for one year and realizes water saving target. The design and application study result of this water saving system engineering can be extended.
出处
《能源工程》
2003年第4期59-62,共4页
Energy Engineering
关键词
酒店
节水系统
工程设计
中水回用
膜生物反应器
蒸汽凝结水回用
终端节水器
hotel
water saving system engineering
secondary water reuse
membrane bio\|reactor(MBR)
steam condensing water reuse
terminal water saving unit