摘要
本文介绍了Nd :YAG倍频激光眼科治疗机的总体结构。由于采用了指示光和治疗光为同一光束的思想 ,使定位更加准确。更换激光电源后 ,在改动尽可能小的情况下 ,重新设计了控制系统中的F/V转换电路 ,使之能够与原控制系统匹配。并优化软件部分的算法 。
This paper describes the structure of a Nd:YAG double frequency therapeutic instrument used for ophthalmology. Due to the indication light and treatment light is the same beam, the design of optical system becomes simplified. Because the laser power was changed, we redesign the F/V circuit to make it adapt to the old system. After optimization of the software, the stability and security of the system is enhanced.
出处
《应用激光》
CSCD
北大核心
2003年第4期235-236,254,共3页
Applied Laser