期刊文献+

瓣环扩大技术在小主动脉瓣环瓣膜置换术中的应用 被引量:3

下载PDF
导出
摘要 目的 :总结主动脉瓣环扩大术在小主动脉瓣环换瓣术中的应用经验。方法 :2009年2月~2014年1月我院收治小主动脉瓣环患者19例,采用Manouguian法、Nicks法扩大瓣环,再置入合适型号的机械瓣。同期行二尖瓣机械瓣置换并三尖瓣成形2例、左室流出道疏通1例。结果 :19例均痊愈出院,术后早期无严重并发症(低心排综合征、二次开胸止血、恶性心律失常)。术后随访6-36个月无死亡,心功能均Ⅰ-Ⅱ级,心脏彩超检查主动脉瓣跨瓣压差和瓣口流速均显著降低。其中一例Manouguian法扩大瓣环并置入18mm ATS AP瓣患者术后3个月时发生Ⅲ°房室传导阻滞,行永久起搏器置入后恢复出院。结论 :小主动脉瓣环患者在主动脉瓣置换时行瓣环扩大成形,能获得满意的近期效果,是一种安全有效的术式。瓣环扩大的关键在于严格把握指证、恰当选择术式。
出处 《当代医药论丛》 2014年第17期223-224,共2页
  • 相关文献

参考文献7

二级参考文献59

  • 1杨建,张尔永,肖锡俊,石应康,田子朴,黄旭中.主动脉瓣环扩大成形在双瓣膜置换术中的应用[J].中国胸心血管外科临床杂志,2005,12(4):303-304. 被引量:6
  • 2Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis- patient mismatch in the aortic valve position and its prevention. J Am Coil Cardiol,2000,36:1131 - 1141. 被引量:1
  • 3St. Bammos K, Ketikoglou DG, Koullias GJ, et al. The Nicks-Nunez posterior enlargement in the small aorcic annulus: immediate-intermediate results. Inter Cardiovasc Thorac Surg,2006,5:749- 753. 被引量:1
  • 4Dillard DH, Miller Jr. DW. Enlargement of the aortic root//Atlas of cardiac surgery. New York: McMillan Inc,1983:104- 107. 被引量:1
  • 5Ruel M,A1 Faleh H,Kulik A,Chan K L,Mesana T G,Burwash I G. Prosthesis-patient mismatch after aortic valve replacement predominantly affects patients with preexisting left ventricular dysfunction:effect on survival, freedom from heart failure, and left ventrieular mass regression[J]. J Thorac Cardiovasc Surg, 2006,131 : 1036-1044. 被引量:1
  • 6Kulik A,Burwash I G,Kapila V,Mesana T G,Ruel M. Long term outcomes after valve replacement for low-gradient aortic stenosis: impact of prosthesis-patient mismatch [J]. Circulation,2006,114(1 Suppl) :I553-I558. 被引量:1
  • 7Tasea G, Brunelli F, Cirillo M, Dalla Tomha M, Mhagna Z, Troise G, et al. Impact of the improvement of valve area achieved with aortic valve replacement on the regression of left ventricular hypertrophy in patients with pure aortic stenosis [J].Ann Thorac Surg, 2005,79 : 1291-1296. 被引量:1
  • 8Price J, Lapierre H, Ressler L, I.am B K, Mesana T G, Ruel M. Prosthesis-patient mismatch is less frequent and more clinically indolent in patients operated for aortic insufficiency[J]. J Thorac Cardiovasc Surg, 2009,138 :639-645. 被引量:1
  • 9Brown M L,Schaff H V,Suri R M,Li Z,Sundt T M,Dearani J A, et al. Regression in left ventricular mass after aortic valve re placement for chronic aortic regurgitation is unrelated to prosthetic valve size[J]. J Thorac Cardiovasc Surg, 2010 Nov 10. [Epub ahead of print]. 被引量:1
  • 10Blais C,Dumesnil J G,Baillot R,Simard S,Doyle D,Pibarot P Impact of valve prosthesis-patient mismatch on short term mor tality after aortic valve replacement[J]. Circulation, 2003,108 :983- 988. 被引量:1

共引文献10