摘要
振动沉管灌注桩是一种广泛运用的桩型,但其施工工艺较复杂,稍有疏忽就容易导致施工质量问题,如出现断桩、缩颈、管内进泥水、吊脚桩等。在施工中应对出现的问题及时进行分析,并提出相应的防范方法和质量控制措施,才能保证振动沉管灌注桩的施工质量。
The vibration driven castinplace pile is widely applied in the foundation reinforcement project. Due to its complex construction technology, any carelessness would easily cause poor construction quality. In the construction, the problems should be analyzed and treated timely and some protective measures and quality control countermeasures should be formulated in order to guarantee the construction quality of vibration driven castinplace pile.
出处
《水力发电》
北大核心
2003年第8期52-54,共3页
Water Power
关键词
振动沉管灌注桩
质量控制
施工程序
质量评定
美林防洪堤工程
vibration driven cast-in-place pile, quality control, construction procedure, quality evaluation, Meilin Flood Protection Embankment Project