期刊文献+

多层螺旋CT脑血管成像的临床应用

Clinical Application of Multi-slice CT in Cerebral Vascular Image
下载PDF
导出
摘要 目的 :探讨多层螺旋CT脑血管成像的方法与临床应用价值。方法 :对 18例病人用西门子Sensa tion 4四层螺旋CT机按照CT脑血管成像参数进行扫描 ,然后将所获图像数据导入CT 3D工作站 ,利用后处理软件———MPR、MIP、SSD、VRT、CTVE进行成像 ,由两位放射科医生和两位内科医生对图像进行分析。结果 :18例中 ,正常 8例 ,脑动脉瘤 1例 ,血管狭窄 3例 ,动静脉畸形 2例 ,脑肿瘤 4例。几种后处理软件———MPR、MIP、SSD、VRT都能清楚地显示脑血管 ,尤其以MIP效果最好 ;CTVE的优势在于显示血管腔内情况。结论 :多层螺旋CT脑血管成像具有安全、无创、准确的优点 ,可部分替代DSA。 Objective: To study the method and clinical application value of multi-slice CT in cerebral vascular image.Methods:18 cases were performed with the Siemens Sensation 4 four-slice spiral CT, according to the parameters of CT brain blood vessel resemble to scan, then the row date was transmitted to the CT 3 D work station, Source images were processed by post-processing software- the MPR, MIP, SSD, VRT, CTVE . All of images were analysed by 2 radiologists and 2 physician .Results:The cases included normal (n=8), brain aneurysm(n=1), vessel stenosis (n=3),arteriovenous abnormality(n=2), brain tumor(n=4). Several kinds of post-processing software -the MPR, MIP, SSD, VRT could all show the brain blood vessel clearly, the MIP was the best among them . The CTVE has more advantages on that showing vessel cavities.Conclusion:Brain blood vessel resemble with multi-slice CT was a safe , noninvasive and accurate method in displaying brain blood vessel. It could even partly replace the DSA.
出处 《中西医结合心脑血管病杂志》 2003年第6期329-331,共3页 Chinese Journal of Integrative Medicine on Cardio-Cerebrovascular Disease
关键词 多层螺旋CT 脑血管成像 临床应用 脑动脉瘤 血管狭窄 动静脉畸形 Multi-slice CT Cerebral vascular image Angiography
  • 相关文献

参考文献7

二级参考文献52

  • 1柳澄,秦维昌.多层螺旋CT(一)[J].医学影像学杂志,2000,10(3):194-195. 被引量:42
  • 2[1]Rubin GD,Dake MD,Semba CP.Current status of three-dimensional spiral CT scanning for imaging the vasculature[J]. Radiol Clin North Am, 1995,33(1):51. 被引量:1
  • 3[2]Soyer P, Bluemke DA, Bliss DF, et al.Surgical segmental anatomy of the liver: demonstration with spiral CT during arterial portography and multiplannar reconstruction[J]. AJR, 1994,13(1):99. 被引量:1
  • 4[3]Costello P, Ecker CP, Tello R, et al.Assessment of the thoracic aorta by spiral CT[J]. AJR, 1992,158(4):1127. 被引量:1
  • 5[1]McCollough CH, Zink FE. Performance evaluation of a multi-slice CT system. Med Phys, 1999, 26:2223 被引量:1
  • 6[2]Hu H, He HD, Fox SH. Four multidetector-row helical CT: image quality and volume corverage speed. Radiology, 2000, 215:55 被引量:1
  • 7[3]Jones TR, Kaplan RD, Atlas SW,et al. Single-versus multi-detector row CT of the brain: quality assessment. Radiology, 2001, 219:750 被引量:1
  • 8[4]Berland LL, Smith JK. Multidetector-array CT: once again, technology creates new opportunities. Radiology, 1998, 209:327 被引量:1
  • 9[5]Prokop M. Multislice CT angiography. European Journal of Radiology, 2000, 36:86 被引量:1
  • 10[6]Rubin GD, Shivau MC, Kee ST,et al. Aorta and iliac arteries: single versus multiple detector-row helical CT angiography. Radiology, 2000, 215:670 被引量:1

共引文献239

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部