摘要 在进行核电站安全壳结构的整体性能试验时,大气环境作用会干扰结构试验变位和应变的测试结果。为了了解环境影响的规律和幅度,从理论和试验验证上探讨了安全壳在大气环境下的温度场问题,建立了时程分析和估值的计算模式,研究了有关参数。编程计算结果与实测结果非常吻合。本研究对大型结构设计和探讨混凝土和砖混结构建筑顶层开裂的热作用规律也具有实际意义。 The Structural integral test of nuclear power station PCCV is one kind of precision test under low load. The strain and displacement in the process of test will be influence by atmosphere circumstance . The effect of the temperature field under atmosphere circumstance to the PCCV test is studied in detail from both the theory and the test. Both the heat transfer difference e-quations and the elevation formula are established. At same time, a computer program is developed to run some examples. The computing results are well agreed with that of the test.
出处 《土木工程学报》 EI CSCD 北大核心 2003年第6期12-17,共6页 China Civil Engineering Journal
关键词 温度场 太阳辐射 安全壳 结构整体试验 temperature field, solar radiate, PCCV (Prestressed Concrete Containment Volume) , structural integral test
  • 相关文献

参考文献5

  • 1俞昌铭.热传导及其数值分析[M].北京:清华大学出版社,1982.. 被引量:22
  • 2冶金工业部建筑研究总院.秦山核电厂安全壳结构整体性能的检测与研究[M].北京,1991.. 被引量:1
  • 3冶金工业部建筑研究总院.核电站安全壳结构检测技术的研究及其在巴基斯恰希玛核电站中的应用[M].北京,1999.. 被引量:1
  • 4Duffle J A, Beckman W A. Solar Energy Thermal Processes[J] . John Wiley & Sons, 1974. 被引量:1
  • 5Kehibeck F. EinfluB aer Sonnen.~-ahluns bei Brflckenbatr-werken [J]. WERNER-VERL-AG, 1975. 被引量:1

共引文献21

同被引文献23

  • 1黎鹏飞,李忠诚.压水堆核电厂安全壳结构温度效应分析[J].工业建筑,2011,41(S1):140-144. 被引量:4
  • 2刘文燕,耿耀明.混凝土表面太阳辐射吸收率试验研究[J].混凝土与水泥制品,2004(4):8-11. 被引量:28
  • 3Kenji Yonezawa,Katsuyoshi Imoto.Ultimate capacity analysis of 1/4 PCCV model subjected to internal pressure [J].Nuclear Engineering and Design,2002:357-379. 被引量:1
  • 4Song Ha-Won,Nam Sang-Hyeok,Byul Shim,Kim Sang-Hyo.Path-dependent nonlinear analysis of a concrete reactor containment vessel subjected to internal pressure using a volume control technique [J].Engineering Structures,2009,31(4):990-998. 被引量:1
  • 5Hu Hsuan-Teh,Lin Yu-Hon.Ultimate analysis of PWR prestressed concrete containment subjected to internal pressure [J].International Journal of Pressure Vessels and Piping,2006,83(3):161-167. 被引量:1
  • 6EJ/T926-95,压水堆核电厂预应力混凝土安全壳设计规范[S].中国核工业总公司,1995. 被引量:1
  • 7Vitharana,N D,Priestley M J N.Significance of temperature-induced loadings on concrete cylindrical reservoir walls [J].ACI Journal,1999,96(5):737-749. 被引量:1
  • 8宋玉普.预应力混凝土特种结构[M].北京:机械工业出版社,2008. 被引量:7
  • 9Kenji Yonezawa,Katsuyoshi Imoto.Analytical study on structural failure mode of 1/4 PCCV test model.SMiRT 17th [C].Prague,Czech Republic,August 17-22,2003. 被引量:1
  • 10张会东,林松涛,王永焕.核电厂安全壳结构的内压承载能力计算分析[J].工业建筑,2007,37(8):43-46. 被引量:17

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部