期刊文献+

Mitigation of power system forced oscillations based on unified power flow controller 被引量:1

Mitigation of power system forced oscillations based on unified power flow controller
原文传递
导出
摘要 Forced oscillations(FOs), or low-frequency oscillations(LFOs) caused by periodic, continuous, small power disturbances, threaten the security and stability of power systems.Flexible AC transmission system(FACTS)devices can effectively mitigate LFOs via stability control.We propose a novel method that mitigates FOs by shifting the resonant frequency.Based on the features of the linearized swing equation of a generator, a resonant frequency shift can be achieved by controlling the synchronous torque coefficient using a unified power flow controller(UPFC).Because of the resonance mechanism, the steady-state response of an FO can be effectively mitigated when the resonant frequency changes from the original one, which was close to the disturbance frequency.The principle is that a change in resonant frequency affects the resonance condition.Simulations are conducted in a single-machine infinite-bus(SMIB) system, and the simulation results verify that the method is straightforward to implement and can significantly mitigate FOs.The controller robustness when the resonant frequency is not accurately estimated is also analyzed in the simulations. Forced oscillations(FOs), or low-frequency oscillations(LFOs) caused by periodic, continuous, small power disturbances, threaten the security and stability of power systems.Flexible AC transmission system(FACTS)devices can effectively mitigate LFOs via stability control.We propose a novel method that mitigates FOs by shifting the resonant frequency.Based on the features of the linearized swing equation of a generator, a resonant frequency shift can be achieved by controlling the synchronous torque coefficient using a unified power flow controller(UPFC).Because of the resonance mechanism, the steady-state response of an FO can be effectively mitigated when the resonant frequency changes from the original one, which was close to the disturbance frequency.The principle is that a change in resonant frequency affects the resonance condition.Simulations are conducted in a single-machine infinite-bus(SMIB) system, and the simulation results verify that the method is straightforward to implement and can significantly mitigate FOs.The controller robustness when the resonant frequency is not accurately estimated is also analyzed in the simulations.
出处 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第1期99-112,共14页 现代电力系统与清洁能源学报(英文)
基金 supported by National Natural Science Foundation of China (No.51577032) State Grid Corporation of China (No.5210K017000C)
关键词 FORCED OSCILLATIONS Flexible AC transmission systems UNIFIED power flow CONTROLLER Stability control Forced oscillations Flexible AC transmission systems Unified power flow controller Stability control
  • 相关文献

参考文献7

二级参考文献73

共引文献283

同被引文献14

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部