期刊文献+

室内装饰材料的标准房间/墙角火实验研究进展 被引量:19

Progress in Study of Standard Room/Corner Fire Test of Lining Materials on Enclosure
下载PDF
导出
摘要 标准房间 /墙角火实验是一种全尺度火灾实验研究方法 ,主要用来研究室内装饰材料的火灾特性。介绍了ISO 970 5房间 /墙角火实验方法的原理和实验装置 ,以及国内外利用该方法对装饰材料火灾特性进行研究的进展情况 ,包括对材料热释放速率、烟气产生和室内火蔓延方面的研究。分析了其研究成果在室内装饰材料的分类及火灾危险性评估中的实际应用情况 。 Standard room/corner fire test is a full scale reaction to fire research method. It's mainly used to evaluate lining materials on enclosure. This paper introduces the principles and experimental devices of ISO 9705 room/corner fire test, and describes the progress in study on fire behavior of linings, which is under this method, including the researches of lining materials' HRR (Heat Release Rate), RSP (Rate of Smoke Production) and surface flame spread process. Furthermore, the application of results on the classification and fire hazard evaluation of lining materials is analyzed. At last of this paper, some future work in this field is ponited out. [
出处 《中国工程科学》 2003年第4期55-60,共6页 Strategic Study of CAE
基金 国家自然科学基金资助项目 ( 5 0 0 760 41) 国家重点基础研究专项经费资助项目 ( 2 0 0 1CB40 960 3 0 2 )
关键词 室内装饰材料 全尺度火灾实验研究 火灾特性 标准房间/墙角火实验 火灾动力学模型 lining materials full scale ISO 9705 room/corner fire test
  • 相关文献

参考文献3

二级参考文献57

  • 1范维澄 王清安.火灾简明学教程[M].合肥:中国科学技术大学出版社,1995.. 被引量:5
  • 2[1]Levin B C,et al.Further development of the n-gas mathematical model.American Chemical Society,1995,Chapter20 被引量:1
  • 3[2]Gottuk D T,et al.Carbon monoxide production in compartment fires.Journal of Fire Protection Engineering.1992,4:133 被引量:1
  • 4[3]Debanne S M,et al.The importance of carbon monoxide in the tox-icity of fire atmospheres.Fire Hazard and Fire Risk Assessment,ASTM STP1150,1992,9 被引量:1
  • 5[4]Nelson G L.Carbon monoxide and fire toxicity:A review and anal-ysis of recent work.Fire Technology,1998,34(1):39 被引量:1
  • 6[5]Lattimer B Y.Carbon monoxide levels in structure fires:Effects of wood in the upper layer of a post-flashover compartment fire.Fire Technology,1998,34(4):325 被引量:1
  • 7[6]Gann R G,et al.Fire conditions for smoke toxicity measurement.Fire and Materials,1994,18:193 被引量:1
  • 8[7]Babrauskas V,et al.The role of bench-scale test data in assessing real-scale fire toxicity.NIST Technical Note1284,January1991 被引量:1
  • 9[8]Gann R G,et al.Toxicity data for fire hazard analysis.In:Pro-ceedings of12th Joint Panel Meeting of the UJNR Panel on Fire Re-search and Safety,Oct.27-Nov.2,1992 被引量:1
  • 10[9]Babrauskas V,et al.A methodology for obtaining and using toxic potency data for fire hazard analysis.Fire Safety Journal,1998,31:345 被引量:1