摘要
针对SS3B型电力机车多次发生高压连接器水平脱离进而引起机破的问题进行了探讨。通过对机车现有设计资料分析计算,明确故障根源,并提出了可靠的低成本改造措施,以杜绝此类故障再次发生。
The problem of high pressure connector horizontal disengagement which occurred many times in SS3 B electric locomotive was discussed. By locomotive existing design data analysis and calculation, failure causes were identified and reliable low-cost modification measures were proposed to prevent a recurrence of such failures.
出处
《铁道机车与动车》
2015年第3期18-21,5,共5页
Railway Locomotive and Motor Car
关键词
SS3B型电力机车
高压连接器
水平脱离
安装座
SS3B electric locomotive
high pressure connector
horizontal disengagement
mounting base