摘要
分析了锅内汽水变化对水位计的影响,并通过对水位计形式、结构、原理、使用过程的分析,阐述了由此而引起的锅炉缺水事故及其处理、预防措施。
The paper analyses how the watersteam transformation in a boiler drumeffects the water level meter and discusses how, according to the meters differences in type, construction, principle of function as well as way of usage, water deficiency failures of boiler and handing preventing measures may occur.
出处
《发电设备》
2003年第2期19-21,29,共4页
Power Equipment
关键词
锅炉缺水
水位表
事故分析
boiler water deficiency
water level meter