摘要 局部放电声信号对于检测电力电容器的绝缘特性有着重要意义。笔者采用声检测装置采集电力电容器局部放电声信号,并且分析了局部放电信号的特点,介绍了3类典型信号的特点和形成原因。同时应用了窄带滤波和小波降噪的方法来抑制噪声,取得了满意的效果。 Acoustic signals of partial discharge are very important for detecting insulation characters in power capacitors.In this paper an acoustic detecting instrument is used to collect the acoustic signals of partial discharge in power capacitors,and characteristics of these signals are analyzed.Therefore,characteristics of three kinds of typical signals and reasons of their formation are introduced.At the same time,rejection of narrow-band wave and denoising using wavelet are introduced to reject noises.The outcome is satisfying.
机构地区 清华大学电机系
出处 《高压电器》 CAS CSCD 北大核心 2003年第2期4-6,共3页 High Voltage Apparatus
基金 国家自然科学基金资助项目(59977011)
关键词 电力电容器 局部放电 声信号分析 绝缘特性 power capacitors partial discharge acoustic signal denoising
  • 相关文献

参考文献1

二级参考文献2

  • 1[1]Ghirelli L, Koltunowicz W etal.Acoustic method for partial discharge detection in high power capacitors. IEE Conference Publication procee dings of the International Conference on Partial Discharge, 1993, 92 被引量:1
  • 2[2]Robert Meunier, Georges H V. Propagation behavior of acoustic partial dischar ge signals in oil-filled transformers. Roam: Conference Records of the ECDL'96 1 2th International Conference and Breakdown in Dielectric Liquids, 1996, 401 被引量:1