期刊文献+

PSS用作高能量分辨率微量元素分析的可行性研究

Study of Feasibility on the Trace Element Analysis with High-Energy Resolution by PSS
原文传递
导出
摘要 在同步光源上 ,用PSS进行了高能量分辨率元素分析的可行性研究 .其结果是 :对含Ti和Cu的薄样品 ,绝对检测量可达 10 - 10 g级 ;对轻基体样品 ,Cr的探测限可达 1— 10ppm ;并且在含Cr的均匀液体样品中Cr峰面积积分净计数与其含量有良好的正比关系 .这些结果表明 。 The paper presents the study of feasibility on the trace element analysis with high energy resolution by PSS at synchrotron radiation as an exciting source. Results are that the absolute value of ~10 -10 g has been measured for elements of Ti and Cu in thin sample, the detection limit is about 1-10ppm order of magnitude for Cr in the substance of light base, and a well proportional relation exists between the counts of net integrated area and the concentration of Cr in the samples of homogenized solution. These show that the PSS is feasible as a useful tool to analyze element with high energy resolution.
出处 《高能物理与核物理》 CSCD 北大核心 2003年第3期273-276,共4页 High Energy Physics and Nuclear Physics
基金 国家自然科学基金 ( 19875 0 64 )资助 北京正负电子对撞机国家实验室的BSRF支持~~
关键词 PSS 高能量分辨率 探测限 正比关系 微量元素分析 可行性研究 平面晶体波长色散式位置灵敏谱仪 PSS, high energy resolution, detection limit, proportional relation
  • 相关文献

参考文献7

  • 1[1]Trk I, Terasawa, Petukhov, Inter. J. of PIXE, 1999, 9(3,4):161 被引量:1
  • 2[2]Maeda K, Hamanaka H, Hasegawa K, Inter. J. of PIXE, 1996, 6(1,2):97 被引量:1
  • 3[3]More D H, Bench G S, Freeman S et al. Nucl. Instr. And Meth., 1995, B99:427 被引量:1
  • 4[4]Hayashi S, Taniguchi J, Teramoto A et al. Nucl. Instr. And Meth., 1992, B64:428 被引量:1
  • 5[6]HU Zhao-Hui, LIU Shi-Jie, LIU Ping-Sheng et al. Inter. J. of PIXE, 1999, 9(3-4):125 被引量:1
  • 6[7]Hamanaka H, Ohura M, Yamamoto Y et al. Nucl. Instr. And Meth., 1988, B35:75 被引量:1
  • 7[8]Budnar G M. Nucl. Instr. And Meth., 1996, B109/110:144 被引量:1