期刊文献+

氡子体气溶胶分离器的研制 被引量:1

Separators of radon and thoron daughter aerosol
下载PDF
导出
摘要 为提高放射性气溶胶监测仪的灵敏度,消除天然本底即氡子体气溶胶的干扰是极为重要的。氡子体气溶胶分离器是利用氡子体气溶胶与人工放射性气溶胶的粒度特征的不同进行粒度分离采样的采样装置。将这种分离采样装置用于放射性气溶胶监测仪,在采样过程中将天然本底气溶胶预选掉大部分甚至绝大部分,这对于提高放射性气溶胶监测仪的灵敏度有极大的意义。本文对分离器的工作原理、刻度方法、实验结果以及需要注意的问题进行了介绍和讨论。 To improve the detectable limit of radioactive aerosol monitors, it is very important to eliminate the inter-ference of the natural background, i.e. radon and thoron daughter aerosol. A particle size selective separator is used as artificial radioactive aerosol sampler. This separator may keep artificial aerosol from the natural radon and thoron daughter aerosol base on their different particle sizes. With the aid of the separator, most of natural background aero-sol can be rejected in sampling radioactive aerosols, which is very helpful to improving sensitivity of the radioactive aerosol monitors. The separation principle and calibration method of the separator are presented,test results are given, and some problems one must pay attention to are discussed in the paper.
出处 《核技术》 CAS CSCD 北大核心 2003年第4期315-320,共6页 Nuclear Techniques
关键词 氡Tu子体 人工放射性气溶胶 分离器 切割直径 压缩比 监测仪 Radon and thoron daughter, Artificial radioactive aerosol, Separator, Cut out diameter, Rejection radio
  • 相关文献

参考文献10

二级参考文献22

  • 1卢正永,李爱武,苟全录,傅翠明,李静韬,严涛.α-β放射性气溶胶快速监测仪的研制[J].原子能科学技术,1996,30(2):112-117. 被引量:8
  • 2李爱武 张志龙 等.CAM-1型放射性气溶胶连续监测仪[M].太原:中国辐射防护研究院,1999.. 被引量:1
  • 3辉群.放射性气溶胶监测方法[J].核防护,1977,(1):1-1. 被引量:1
  • 4卢正永.放射性气溶胶监测方法简介.全国第三届气溶胶学术会议论文集[M].太原,1994.. 被引量:1
  • 5张志龙.连续自动气溶胶监测仪的功能和程序设计[M].中国辐射防护研究院,1999.. 被引量:1
  • 6卢正永.国外放射性气溶胶连续监测仪性能综述[M].中国辐射防护研究院,1999.. 被引量:1
  • 7卢正永,1987年 被引量:1
  • 8卢正永,辐射防护,1986年,6卷,2期,101页 被引量:1
  • 9梁鸿富,辐射防护,1983年,3卷,4期,276页 被引量:1
  • 10卢正永,1982年 被引量:1

共引文献37

同被引文献13

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部