摘要 给出近红外光谱分析技术中测量精度与仪器精度和测量方法之间的传递函数,并通过葡萄糖水溶液浓度测量的基础研究进行了验证和分析.结果表明,它不仅能为光谱方法可达到的测量精度提供一种估计手段,还可以给出采用不同测量方法时实现预期测量精度所必需的仪器精度.这为血糖无创伤检测技术乃至近红外光谱分析技术的设计实现及其测量精度分析提供了理论依据. Noninvasive measurement of blood glucose is a focal topic in the world.The mathematic relations regarding instrument precision,regression method and prediction accuracy are put forward.They are tested and analyzed through the determination of glucose concentration in an aqueous solution with nearinfrared(NIR) spectroscopy and chemometrics.The results show that the propagation functions provide a prediction accuracy estimate method for spectroscopic measurement.In addition,they can determine the necessary instrumental requirement for the expected prediction accuracy when certain regression method is used.This enables theoretic guides to the measuring methods and references for prediction accuracy analysis of the noninvasive glucose measurement and even the nearinfrared spectroscopy. 
出处 《天津大学学报(自然科学与工程技术版)》 EI CAS CSCD 北大核心 2003年第2期139-142,共4页 Journal of Tianjin University:Science and Technology
基金 国家"十五"科技攻关基金资助项目(2001BA706B-21) 教育部科学技术研究重点基金资助项目
关键词 血糖浓度 无创伤检测 测量精度 仪器精度 偏最小二乘法 化学计量 blood glucose concentration noninvasive measurement prediction accuracy instrument precision partial last-squares chemometrics
  • 相关文献

参考文献9

  • 1Arnold Mark A,Small Gary W.Determination of physiological levels of glucose in an aqueous matrix with digitally filtered fourier transform near-infrared spectra[J].Analytical Chemistry,1990,62(14):1457-1464. 被引量:1
  • 2Hazen Kevin H,Arnold Mark A,Small Gary W.Temperature-insensitive near-infrared spectro scopic measurement of glucose in aqueous solutions[J].Applied Spectroscopy,1994,48(4):477-483. 被引量:1
  • 3Pan Shengtian,Chung Hoeil,Arnold Mark A.Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerudes[J].Analytical Chemistry,1996,68(7):1124-1134. 被引量:1
  • 4Rorbert D Rosenthal.Non-invasive measurement of blood glucose[P].USA:USP 5028787,1991-07-02. 被引量:1
  • 5Russell H Barnes.Non-invasive determination of glucose concentration in body of patients[P].USA:USP 5070874,1991-12-10. 被引量:1
  • 6Andrew J Berger,Michael S Feld.Analytical method of estimating chemometric prediction error[J].Applied Spectroscopy,1997,51(5):725-731. 被引量:1
  • 7Hazen Kevin H,Arnold Mark A,Small Gary W.Measurement of glucose in water with first-overtone near-infrared spectra[J].Applied Spectroscopy,1998,52(12):1597-1605. 被引量:1
  • 8Delphine Jouan-Rimbaud,Riccardo Leardi.Genetic algorithms as a tool wavelength selection in multivariate calibration[J].Analytical Chemistry,1995,67(23):4295-4301. 被引量:1
  • 9Bangalore Arjun S,Shaffer Ronald E,Small Gary W et al.Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression:Application to near-infrared spectroscopy[J].Analytical Chemistry,1996,68(23):4200-4212. 被引量:1