摘要 当火灾中钢框架柱不均匀受火时,会在截面和高度方向产生温度梯度。现行规范给出了火灾中钢构件升温的计算公式,但这些公式均是基于温度沿构件高度和截面均匀分布的假设。采用有限元方法研究了火灾中两相邻面受火钢柱的截面温度场,火灾场景采用ISO834标准升温曲线,钢柱采用非膨胀型防火涂料保护。对于所研究的两相邻面受火钢柱,沿截面宽度和高度方向均存在温度梯度。基于参数分析结果,对欧洲规范EN 1993-1-2中钢构件升温计算公式进行了修正,来计算两相邻面受火钢柱截面各部分的升温曲线。 Temperature gradient will occur when a steel column is heated non-uniformly in a fire.Current codes for structural fire design provide the design equations to calculate the temperature development of steel columns in a fire.However,the design equations are based on the assumption that the temperature distribution is uniform across the section.The temperature field of steel columns across the section with two adjacent sides exposed to ISO834 standard fire is analyzed using finite element method.The columns are protected by non-intumescent fire coatings.For the column exposed to fire from two adjacent sides,thermal gradient exists both along the width and depth of the H-section.The design equation in EN1993-1-2based on the element factor approach is modified through parameter analysis.Simplified temperature distribution profiles are proposed based on the finite element simulation results.
作者 夏金环 王培军 周吉学 XIA Jinhuan;WANG Peijun;ZHOU Jixue(Shandong Provincial Key Laboratory for High Strength Lightweight Metallic Materials,Advanced Materials Institute,Qilu University of Technology(Shandong Academy of Sciences),Jinan 250014,China;School of Civil Engineering,Shandong University,Jinan 250061,China)
出处 《建筑钢结构进展》 CSCD 北大核心 2019年第1期80-88,94,共10页 Progress in Steel Building Structures
关键词 钢柱 两相邻面受火 温度分布 非膨胀型防火涂料 温度梯度 参数分析 计算公式 steel column heated from two adjacent sides temperature distribution non-intumescent fire coating temperature gradient parameter analysis design equation
  • 相关文献

参考文献2

二级参考文献13

  • 1吴波,洪洲.钢筋混凝土柱的耐火极限研究[J].自然灾害学报,2005,14(5):119-126. 被引量:12
  • 2吴波,徐玉野.钢筋混凝土T形柱的耐火极限研究[J].土木工程学报,2007,40(3):32-39. 被引量:16
  • 3吴波,唐贵和,王超.不同受火方式下混凝土柱耐火性能的试验研究[J].土木工程学报,2007,40(4):27-31. 被引量:33
  • 4Tan K H, Yao Y. Fire resistance of four-face heated reinforced concrete columns [J]. Journal of Structural Engineering, 2003, 129(9): 1220- 1229. 被引量:1
  • 5Tan K H, Yao Y. Fire resistance of reinforced concrete columns subjected to 1-, 2-, and 3-face heating [J]. Journal of Structural Engineering, 2004, 130(11): 1820- 1828. 被引量:1
  • 6Wu B, Xu Yuye. Nonlinear finite element analysis of transient thermal field for RC special-shaped columns in fire [C]//Han Linhai, Ru Jiping, Tao Zhong. Proceedings of the 9th International Symposium on Structural Engineering for Young Experts. Fuzhou & Xiamen China: Science Press, 2006, 1/2: 987-993. 被引量:1
  • 7Uy B. Concrete-Filled Fabricated Steel Box Columns for Multistory Buildings : Behavior and Design [ J ] . Progress. in Structural Engineering and Materials, 1998, 1 (2) : 150 - 158. 被引量:1
  • 8Forbes D. Three Tall Buildings in Southern China[ J]. Structural Engineering International, 1997, 7 (3) : 157 - 159. 被引量:1