针对综合医院中医用磁共振成像设备、医用X射线设备、医用高能射线设备、医用核素设备等大型诊疗设备的特性要求,将供配电设计中工作制式、设备容量、供电要求、接地要求等一些常见问题及注意事项,进行了归纳、分析和总结。
Some common problems and precautions,such as the working systems,equipment capacity,power supply requirements,and grounding requirements in the power supply and distribution design,are summarized,analyzed and generalized according to the characteristic requirements of largescale diagnosis and treatment equipment in general hospitals,such as magnetic resonance imaging equipment,medical X-ray equipment,medical highenergy ray equipment,and medical nuclide equipment.
作者
梁志超
文露
LIANG Zhichao;WEN Lu(Hu’nan Architectural Design Institute Limited Company,Changsha 410012,China)
出处
《建筑电气》
2019年第9期26-29,共4页
Building Electricity
关键词
综合医院
医院等级划分
诊疗设备
电气设计
供电要求
工作制式
设备容量
接地
general hospital
hospital grade division
diagnosis and treatment equipment
electrical design
power supply requirements
working system
equipment capacity
grounding