摘要
根据电压波动与闪烁测试标准对空调产品的特殊测试要求进行了分析,详细完整地介绍了空调电压波动与闪烁所有指标参数的测试方法步骤,最后介绍了当测试结果不合格时,按有条件设备接入电网时阻抗的计算方法和处理方式处理。
According to the test standard of voltage fluctuations and flicker, the air-conditioner test is exceptive. This article describes detailedly the assessment methods of all parameter of voltage fluctuations and flicker for Air-conditioner. In the end, it introduces the measurement method of impedance and disposal manner when the air-conditioner does not comply with the limits of IEC 61000-3-3, and which therefore cannot be declared compliant with this standard, may be retested or evaluated the reference impedance to show conformity with IEC 61000-3-11.
出处
《家电科技》
2014年第11期42-44,共3页
Journal of Appliance Science & Technology
关键词
空调
电压波动与闪烁
解析法
阻抗
Air-conditioner
Voltage fluctuations and flicker
Analytical method
Impedance